Usefulness of microsimulation to translate valve performance into patient outcome: patient prognosis after aortic valve replacement with the Carpentier-Edwards supra-annular valve
- PMID: 17723821
- DOI: 10.1016/j.jtcvs.2007.03.051
Usefulness of microsimulation to translate valve performance into patient outcome: patient prognosis after aortic valve replacement with the Carpentier-Edwards supra-annular valve
Abstract
Objective: Numerous reports have been published documenting the results of aortic valve replacement. It is often not easy to translate these outcomes involving the condition of the valve into the actual consequences for the patient. We previously developed an alternative method to study outcome after aortic valve replacement that allows direct estimation of patient outcome after aortic valve replacement: microsimulation modeling. The goal of this article is to provide insight into microsimulation methodology and to give an overview of the advantages and disadvantages of simulation methods (in particular microsimulation) in comparison with standard methods of outcome analysis.
Methods: By using a primary dataset containing 1847 patients and 14,429 patient-years, advantages and disadvantages of standard methods of outcome analysis are discussed, and the potential role of microsimulation is illustrated by means of a step-by-step explanation of building, testing, and using such a model.
Results: Total life expectancy, event-free life expectancy, and reoperation-free life expectancy for a 65-year-old male patient were 10.6 years, 9.2 years, and 9.8 years, respectively. Lifetime risk of reoperation due to structural valve deterioration was 13.3%.
Conclusions: Microsimulation is capable of providing accurate estimates of age-related life expectancy and lifetime risk of reoperation for patients who underwent aortic valve replacement with the Carpentier-Edwards supra-annular valve. It provides a useful tool to facilitate and optimize the choice for a specific heart valve prosthesis in a particular patient.
Similar articles
-
Prognosis after aortic valve replacement with the Carpentier-Edwards pericardial valve: use of microsimulation.Ann Thorac Surg. 2005 Sep;80(3):825-31. doi: 10.1016/j.athoracsur.2005.03.064. Ann Thorac Surg. 2005. PMID: 16122436 Review.
-
Patient outcome after aortic valve replacement with a mechanical or biological prosthesis: weighing lifetime anticoagulant-related event risk against reoperation risk.J Thorac Cardiovasc Surg. 2009 Apr;137(4):881-6, 886e1-5. doi: 10.1016/j.jtcvs.2008.09.028. Epub 2009 Feb 25. J Thorac Cardiovasc Surg. 2009. PMID: 19327512
-
Comparison of Carpentier-Edwards pericardial and supraannular bioprostheses in aortic valve replacement.Eur J Cardiothorac Surg. 2006 Mar;29(3):374-9. doi: 10.1016/j.ejcts.2005.11.037. Epub 2006 Jan 18. Eur J Cardiothorac Surg. 2006. PMID: 16386920 Review.
-
Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation.Heart. 2004 Oct;90(10):1172-8. doi: 10.1136/hrt.2003.013102. Heart. 2004. PMID: 15367517 Free PMC article.
-
Predicted patient outcome after aortic valve replacement with Medtronic Stentless Freestyle bioprostheses.J Heart Valve Dis. 2007 Jul;16(4):423-8; discussion 429. J Heart Valve Dis. 2007. PMID: 17702369
Cited by
-
Congenital heart defect repair with ADAPT tissue engineered pericardium scaffold: An early-stage health economic model.PLoS One. 2018 Sep 27;13(9):e0204643. doi: 10.1371/journal.pone.0204643. eCollection 2018. PLoS One. 2018. PMID: 30261033 Free PMC article.
-
Influence of the characteristics of Japanese patients on the long-term outcomes after aortic valve replacement: results of a microsimulation.Gen Thorac Cardiovasc Surg. 2015 May;63(5):260-6. doi: 10.1007/s11748-014-0499-2. Epub 2014 Nov 22. Gen Thorac Cardiovasc Surg. 2015. PMID: 25416165 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources