Development of a renal microchip for in vitro distal tubule models
- PMID: 17725364
- DOI: 10.1021/bp0603513
Development of a renal microchip for in vitro distal tubule models
Abstract
Current developments in tissue engineering and microtechnology fields have allowed the proposal of pertinent tools, microchips, to investigate in vitro toxicity. In the framework of the proposed REACH European directive and the 3R recommendations, the purpose of these microtools is to mimic organs in vitro to refine in vitro culture models and to ultimately reduce animal testing. The microchip consists of functional living cell microchambers interconnected by a microfluidic network that allows continuous cell feeding and waste removal controls by fluid microflow. To validate this approach, Madin Darby Canine Kidney (MDCK) cells were cultivated inside a polydimethylsiloxane microchip. To assess the cell proliferation and feeding, the number of inoculated cells varied from 5 to 10 x 10(5) cells/microchip (corresponding roughly to 2.5 to 5 x 10(5) cells/cm2) and from four flow rates 0, 10, 25, and 50 microL/min were tested. Morphological observations have shown successful cell attachment and proliferation inside the microchips. The best flow rate appears to be 10 microL/min with which the cell population was multiplied by about 2.2 +/- 0.1 after 4 days of culture, including 3 days of perfusion (in comparison to 1.7 +/- 0.2 at 25 microL/min). At 10 microL/min flow rate, maximal cell population reached about 2.1 +/- 0.2 x 10(6) (corresponding to 7 +/- 0.7 x 10(7) cells/cm(3)). The viability, assessed by trypan blue and lactate deshydrogenase measurements, was found to be above 90% in all experiments. At 10 microL/min, glucose monitoring indicated a cell consumption of 16 +/- 2 microg/h/10(6) cells, whereas the glutamine metabolism was demonstrated with the production of NH3 by the cells about 0.8 +/- 0.4 micromol/day/10(6) cells. Augmentation of the flow rate appeared to increase the glucose consumption and the NH3 production by about 1.5- to 2-fold, in agreement with the tendencies reported in the literature. As a basic chronic toxicity assessment in the microchips, 5 mM and 10 mM ammonium chloride loadings, supplemented in the culture media, at 0, 10, and 25 micaroL/min flow rates were performed. At 10 microL/min, a reduction of 35% of the growth ratio with 5 mM and of 50% at 10 mM was found, whereas at 25 microL/min, a reduction of 10% with 5 mM and of 30% at 10 mM was obtained. Ammonium chloride contributed to increase the glucose consumption and to reduce the NH3 production. The microchip advantages, high surface/volume ratio, and dynamic loadings, coupled with the concordance between the present and literature results dealing with ammonia/ammonium effects on MDCK illustrate the potential of our microchip for wider in vitro chronic toxicity investigations.
Similar articles
-
Microfluidic PDMS (polydimethylsiloxane) bioreactor for large-scale culture of hepatocytes.Biotechnol Prog. 2004 May-Jun;20(3):750-5. doi: 10.1021/bp0300568. Biotechnol Prog. 2004. PMID: 15176878
-
In situ micropatterning technique by cell crushing for co-cultures inside microfluidic biochips.Biomed Microdevices. 2008 Apr;10(2):169-77. doi: 10.1007/s10544-007-9122-y. Epub 2007 Sep 12. Biomed Microdevices. 2008. PMID: 17849187
-
Stimulation of isolated ventricular myocytes within an open architecture microarray.IEEE Trans Biomed Eng. 2005 Mar;52(3):531-8. doi: 10.1109/TBME.2004.842971. IEEE Trans Biomed Eng. 2005. PMID: 15759583
-
Biological cells on microchips: new technologies and applications.Biosens Bioelectron. 2007 Nov 30;23(4):449-58. doi: 10.1016/j.bios.2007.08.006. Epub 2007 Aug 11. Biosens Bioelectron. 2007. PMID: 17881213 Review.
-
Cells on chips.Nature. 2006 Jul 27;442(7101):403-11. doi: 10.1038/nature05063. Nature. 2006. PMID: 16871208 Review.
Cited by
-
Microfabrication of human organs-on-chips.Nat Protoc. 2013 Nov;8(11):2135-57. doi: 10.1038/nprot.2013.137. Epub 2013 Oct 10. Nat Protoc. 2013. PMID: 24113786
-
Microphysiological Systems: Next Generation Systems for Assessing Toxicity and Therapeutic Effects of Nanomaterials.Small Methods. 2020 Jan 16;4(1):1900589. doi: 10.1002/smtd.201900589. Epub 2019 Nov 11. Small Methods. 2020. PMID: 33043130 Free PMC article.
-
Microfluidics meets metabolomics to reveal the impact of Campylobacter jejuni infection on biochemical pathways.Biomed Microdevices. 2016 Jun;18(3):51. doi: 10.1007/s10544-016-0076-9. Biomed Microdevices. 2016. PMID: 27231016 Free PMC article.
-
Kidney-on-a-chip: untapped opportunities.Kidney Int. 2018 Dec;94(6):1073-1086. doi: 10.1016/j.kint.2018.06.034. Epub 2018 Oct 23. Kidney Int. 2018. PMID: 30366681 Free PMC article. Review.
-
Integrated proteomic and transcriptomic investigation of the acetaminophen toxicity in liver microfluidic biochip.PLoS One. 2011;6(8):e21268. doi: 10.1371/journal.pone.0021268. Epub 2011 Aug 8. PLoS One. 2011. PMID: 21857903 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials