Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2007 Apr-Jun;11(2):198-203.

Prospective randomized comparison of cutting and dilating disposable trocars for access during laparoscopic renal surgery

Affiliations
Randomized Controlled Trial

Prospective randomized comparison of cutting and dilating disposable trocars for access during laparoscopic renal surgery

Ramakrishna Venkatesh et al. JSLS. 2007 Apr-Jun.

Abstract

Background and objectives: Traditional trocar tip design for laparoscopic access incorporates cutting blades to penetrate the body wall. More recently, trocars applying tissue dilation have been used that create a smaller defect, seldom requiring fascial wound closure. Four 12-mm commercially available single-use trocar designs were evaluated for postoperative pain.

Methods: The 4-trocar types included 2 cutting (single or pyramidal bladed) and 2 dilating trocars (radially or axially dilating) type. Fifty-six patients undergoing transperitoneal laparoscopic renal surgery were randomized and blinded to one of the 4 trocar types. In each case, trocars were placed in a standard "diamond" configuration: three 12-mm study trocars and a lateral 5-mm trocar that served as a reference point for normalizing patients' pain scores. Postoperative pain based on a visual analog scale and complications were assessed.

Results: No statistically significant difference existed in pain scores between different trocar types or trocar sites at 3-hour, 24-hour, and 1-week postoperative assessment time points. Eight (4.8%) minor complications occurred: bleeding in 7 (4.2%) and 1 (0.6%) wound infection. The radially dilating trocar had more device malfunction (P<0.05) than did the others.

Conclusion: All 4 disposable trocars, muscle cutting or dilating type, were safe and yielded similar postoperative pain scores with or without the fascial wound closure after renal laparoscopy.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
“Diamond” trocar configuration.
Figure 2.
Figure 2.
Trocar tips (left) and trocar types (right)1: pyramidal bladed2; single bladed3; axially dilating4; radially dilating.

Similar articles

Cited by

References

    1. Yim SF, Yuen PM. Randomized double-masked comparison of radially expanding access device and conventional cutting tip trocar in laparoscopy. Obstet Gynecol. 2001;97:435–438 - PubMed
    1. Lam TYD, Lee SW, So HS, Kwok SPY. Radially expanding trocar: A less painful alternative for laparoscopic surgery. J Lap Adv Surg Tech. 2000;10(5):269–273 - PubMed
    1. Kolata RJ, Ransick M, Briggs L, et al. Technical report: comparison of wounds created by non-bladed trocars and pyramidal tip trocars in the pig. J Laparoendosc Adv Surg Tech. 1999;9(5):455–461 - PubMed
    1. Coda A, Bossotti M, Ferri F, et al. Incisional hernia and fascial defect following laparoscopic surgery. Surg Laparosc Endosc Percutan Tech. 1999;9:348–352 - PubMed
    1. Siqueira TM, Jr, Paterson RF, Kuo RL, Stevens LH, Lingeman JE, Shalhav AL. The use of blunt-tipped 12-mm trocars without fascial closure in laparoscopic live donor nephrectomy. JSLS. 2004;8(1):47–50 - PMC - PubMed

Publication types

LinkOut - more resources