Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Nov;293(5):R2112-9.
doi: 10.1152/ajpregu.00202.2007. Epub 2007 Aug 29.

Mechanisms responsible for the enhanced pumping capacity of the in situ winter flounder heart (Pseudopleuronectes americanus)

Affiliations
Free article
Comparative Study

Mechanisms responsible for the enhanced pumping capacity of the in situ winter flounder heart (Pseudopleuronectes americanus)

Paula C Mendonça et al. Am J Physiol Regul Integr Comp Physiol. 2007 Nov.
Free article

Abstract

In situ Starling and power output curves and in vitro pressure-volume curves were determined for winter flounder hearts, as well as the hearts of two other teleosts (Atlantic salmon and cod). In situ maximum cardiac output was not different between the three species (approximately 62 ml.min(-1).kg(-1)). However, because of the small size of the flounder heart, maximum stroke volume per milliliter per gram ventricle was significantly greater (2.3) compared with cod (1.7) and salmon (1.4) and is the highest reported for teleosts. The maximum power output of the flounder heart (7.6 mW/g) was significantly lower than that measured in the salmon (9.7) and similar to the cod (7.8) but was achieved at a much lower output pressure (4.9 vs. 8.0 and 6.2 kPa, respectively). Although the flounder heart could not perform resting levels of cardiac function at subambient pressures, it was much more sensitive to filling pressure, a finding supported by pressure-volume curves, which showed that the flounder's heart chambers were more compliant. Finally, we report that the flounder's bulbus:ventricle mass ratio (0.59) was significantly higher than in the cod (0.37) and salmon (0.22). These data, which support previous studies suggesting that the flatfish cardiovascular system is a high-volume, low-pressure design, show that vis-à-fronte filling is not important in flatfish, and that some fish can achieve high levels of cardiac output by vis-à-tergo filling alone; and suggest that a large compliant bulbus assists the flounder heart in delivering extremely large stroke volumes at pressures that do not become limiting.

PubMed Disclaimer

Publication types

LinkOut - more resources