Volume responsiveness
- PMID: 17762234
- DOI: 10.1097/MCC.0b013e3282ec68b2
Volume responsiveness
Abstract
Purpose of review: In the ICU only half of the patients are volume responsive - that is, they respond to fluid administration by increasing their cardiac output. We aim to summarize the methods available for predicting volume responsiveness, focusing on recent findings in patients with spontaneous breathing activity.
Recent findings: New information mainly comes from studies that have attempted to find accurate predictors of volume responsiveness in cases of spontaneous breathing activity when heart-lung interaction indices cannot be reliably used. Passive leg raising has emerged as a reliable test for this purpose. The hemodynamic response to this maneuver, which induces a transient increase in cardiac preload, has been shown to provide a robust prediction of volume responsiveness. Assessment of the effects of passive leg raising requires real-time measurement of cardiac output/stroke volume or their surrogates.
Summary: Predicting the hemodynamic response to fluid administration in patients with acute circulatory failure is of major importance and numerous methods are now available. While the respiratory variations of stroke volume (or its surrogates) can be used in patients fully adapted to their ventilator, the passive leg-raising test has become a reliable predictive method in patients with spontaneous breathing activity.
Similar articles
-
Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity.Curr Opin Crit Care. 2008 Jun;14(3):334-9. doi: 10.1097/MCC.0b013e3282fd6e1e. Curr Opin Crit Care. 2008. PMID: 18467896 Review.
-
Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis.Crit Care Med. 2010 Mar;38(3):819-25. doi: 10.1097/CCM.0b013e3181c8fe7a. Crit Care Med. 2010. PMID: 20016380
-
Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients.Crit Care. 2006;10(6):R171. doi: 10.1186/cc5123. Crit Care. 2006. PMID: 17163985 Free PMC article. Clinical Trial.
-
Invasive measures of left ventricular preload.Curr Opin Crit Care. 2006 Jun;12(3):235-40. doi: 10.1097/01.ccx.0000224868.86205.53. Curr Opin Crit Care. 2006. PMID: 16672783 Review.
-
Emerging trends in minimally invasive haemodynamic monitoring and optimization of fluid therapy.Eur J Anaesthesiol. 2009 Nov;26(11):893-905. doi: 10.1097/EJA.0b013e3283308e50. Eur J Anaesthesiol. 2009. PMID: 19667998 Review.
Cited by
-
Next-generation, personalised, model-based critical care medicine: a state-of-the art review of in silico virtual patient models, methods, and cohorts, and how to validation them.Biomed Eng Online. 2018 Feb 20;17(1):24. doi: 10.1186/s12938-018-0455-y. Biomed Eng Online. 2018. PMID: 29463246 Free PMC article. Review.
-
Early goal-directed resuscitation of patients with septic shock: current evidence and future directions.Crit Care. 2015 Aug 28;19(1):286. doi: 10.1186/s13054-015-1011-9. Crit Care. 2015. PMID: 26316210 Free PMC article. Review.
-
Passive leg raise testing effectively reduces fluid administration in septic shock after correction of non-compliance to test results.Ann Intensive Care. 2017 Dec;7(1):2. doi: 10.1186/s13613-016-0225-6. Epub 2017 Jan 3. Ann Intensive Care. 2017. PMID: 28050895 Free PMC article.
-
Bench-to-bedside review: functional hemodynamics during surgery - should it be used for all high-risk cases?Crit Care. 2013 Jan 28;17(1):203. doi: 10.1186/cc11448. Crit Care. 2013. PMID: 23356477 Free PMC article. Review.
-
Duration of hemodynamic effects of crystalloids in patients with circulatory shock after initial resuscitation.Ann Intensive Care. 2014 Aug 1;4:25. doi: 10.1186/s13613-014-0025-9. eCollection 2014. Ann Intensive Care. 2014. PMID: 25593742 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials