Meta-Analysis
. 2008 Feb;18(2):217-25.
doi: 10.1007/s00330-007-0743-6. Epub 2007 Sep 1.

Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis

Affiliations
Meta-Analysis

Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis

Michèle Hamon et al. Eur Radiol. 2008 Feb.

Abstract

This study was designed to define the current role of multislice spiral computed tomography (MSCT) for the diagnosis of coronary in-stent restenosis using a meta-analytic process. Restenosis remains a limitation after coronary stent implantation and contributes to a substantial number of coronary re-assessments by conventional invasive coronary angiography (CA). We identified 15 studies (807 patients) evaluating in-stent restenosis by means of both MSCT (>or=16 slices) and conventional CA until February 2007. After data extraction the analysis was performed according to a random-effects model. The analysis pooled the results from 15 studies with a total of 1,175 stents. A substantial number of unassessable stents (13%) were excluded from the analysis underscoring the shortcomings of MSCT. With this major limitation the diagnostic performance of MSCT for in-stent restenosis detection can be summarized as follows: the sensitivity and specificity were 84% [95% confidence interval (CI) 77-89%] and 91% (95% CI 89-93%), respectively, with positive and negative likelihood ratios of 12.2 (95% CI 6.6-22.6) and 0.23 (95% CI 0.17-0.31), respectively, and with a diagnostic odds ratio of 67.9 (95% CI 34.4-134.1). MSCT has shortcomings difficult to overcome in daily practice for in-stent restenosis detection and continues to have moderately high sensitivity and specificity. The diagnostic role of this emerging technology as an alternative to CA for in-stent restenosis detection remains limited.

PubMed Disclaimer

Similar articles

Cited by

References

    1. N Engl J Med. 2006 Feb 2;354(5):483-95 - PubMed
    1. Eur Radiol. 2007 Jan;17 (1):87-96 - PubMed
    1. Acad Radiol. 2006 Dec;13(12 ):1465-73 - PubMed
    1. Heart. 2006 Jan;92 (1):58-61 - PubMed
    1. Radiol Med. 2005 May-Jun;109(5-6):500-7 - PubMed

Publication types

LinkOut - more resources