. 2007 Dec;17(12):3148-56.
doi: 10.1007/s00330-007-0727-6. Epub 2007 Sep 1.

Pulmonary nodule detection on MDCT images: evaluation of diagnostic performance using thin axial images, maximum intensity projections, and computer-assisted detection

Affiliations

Pulmonary nodule detection on MDCT images: evaluation of diagnostic performance using thin axial images, maximum intensity projections, and computer-assisted detection

A Jankowski et al. Eur Radiol. 2007 Dec.

Abstract

This study aimed at evaluating the diagnostic benefits of maximum intensity projections (MIP) and a commercially available computed-assisted detection system (CAD) for the detection of pulmonary nodules on MDCT as compared with standard 1-mm images on lung cancer screening material. Thirty subjects were randomly selected from our database. Three radiologists independently reviewed three types of images: axial 1-mm images, axial MIP slabs, and CAD system detections. Two independent experienced chest radiologists decided which were true-positive nodules. Two hundred eighty-five nodules > or =1 mm were identified as true-positive by consensus of two independent chest radiologists. The detection rates of the three independent observers with 1-mm axial images were 22 +/- 4.8%, 30 +/- 5.3%, and 47 +/- 2.8%; with MIP: 33 +/- 5.4%, 39 +/- 5.7%, and 45 +/- 5.8%; and with CAD: 35 +/- 5.6%, 36 +/- 5.6%, and 36 +/- 5.6%. There was a reading technique effect on the observers' sensitivity for nodule detection: sensitivities with MIP were higher than with 1-mm images or CAD for all nodules (F-values = 0.046). For nodules > or =3 mm, readers' sensitivities were higher with 1-mm images or MIP than with CAD (p < 0.0001). CAD was the most and MIP the less time-consuming technique (p < 0.0001). MIP and CAD reduced the number of overlooked small nodules. As MIP is more sensitive and less time consuming than the CAD we used, we recommend viewing MIP and 1-mm images for the detection of pulmonary nodules.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Rofo. 2001 Sep;173(9):815-21 - PubMed
    1. Radiology. 1995 Oct;197(1):73-8 - PubMed
    1. Radiology. 2003 Jan;226(1):256-62 - PubMed
    1. Radiographics. 1999 Sep-Oct;19(5):1303-11 - PubMed
    1. Eur Radiol. 2004 Oct;14 (10 ):1930-8 - PubMed