Precise atomic force microscope cantilever spring constant calibration using a reference cantilever array
- PMID: 17764361
- DOI: 10.1063/1.2764372
Precise atomic force microscope cantilever spring constant calibration using a reference cantilever array
Abstract
A method for calibrating the stiffness of atomic force microscope (AFM) cantilevers is demonstrated using an array of uniform microfabricated reference cantilevers. A series of force-displacement curves was obtained using a commercial AFM test cantilever on the reference cantilever array, and the data were analyzed using an implied Euler-Bernoulli model to extract the test cantilever spring constant from linear regression fitting. The method offers a factor of 5 improvement over the precision of the usual reference cantilever calibration method and, when combined with the Systeme International traceability potential of the cantilever array, can provide very accurate spring constant calibrations.
Similar articles
-
Cantilever spring constant calibration using laser Doppler vibrometry.Rev Sci Instrum. 2007 Jun;78(6):063701. doi: 10.1063/1.2743272. Rev Sci Instrum. 2007. PMID: 17614610
-
Lateral force microscope calibration using a modified atomic force microscope cantilever.Rev Sci Instrum. 2007 Oct;78(10):106102. doi: 10.1063/1.2789653. Rev Sci Instrum. 2007. PMID: 17979458
-
Direct measurement of cantilever spring constants and correction for cantilever irregularities using an instrumented indenter.Rev Sci Instrum. 2007 Jun;78(6):063708. doi: 10.1063/1.2747095. Rev Sci Instrum. 2007. PMID: 17614617
-
Metrology for ultrasonic applications.Prog Biophys Mol Biol. 2007 Jan-Apr;93(1-3):138-52. doi: 10.1016/j.pbiomolbio.2006.07.023. Epub 2006 Aug 10. Prog Biophys Mol Biol. 2007. PMID: 17081597 Review.
-
A statistical overview on univariate calibration, inverse regression, and detection limits: Application to gas chromatography/mass spectrometry technique.Mass Spectrom Rev. 2007 Jan-Feb;26(1):1-18. doi: 10.1002/mas.20100. Mass Spectrom Rev. 2007. PMID: 16788893 Review.
Cited by
-
Stiffness calibration of qPlus sensors at low temperature through thermal noise measurements.Beilstein J Nanotechnol. 2024 May 23;15:580-602. doi: 10.3762/bjnano.15.50. eCollection 2024. Beilstein J Nanotechnol. 2024. PMID: 38887532 Free PMC article.
-
Measuring the elastic modulus of soft culture surfaces and three-dimensional hydrogels using atomic force microscopy.Nat Protoc. 2021 May;16(5):2418-2449. doi: 10.1038/s41596-021-00495-4. Epub 2021 Apr 14. Nat Protoc. 2021. PMID: 33854255 Free PMC article.
-
Standardized Nanomechanical Atomic Force Microscopy Procedure (SNAP) for Measuring Soft and Biological Samples.Sci Rep. 2017 Jul 11;7(1):5117. doi: 10.1038/s41598-017-05383-0. Sci Rep. 2017. PMID: 28698636 Free PMC article.
-
A direct micropipette-based calibration method for atomic force microscope cantilevers.Rev Sci Instrum. 2009 Jun;80(6):065109. doi: 10.1063/1.3152220. Rev Sci Instrum. 2009. PMID: 19566228 Free PMC article.
-
A guide for nanomechanical characterization of soft matter via AFM: From mode selection to data reporting.STAR Protoc. 2025 Jun 20;6(2):103809. doi: 10.1016/j.xpro.2025.103809. Epub 2025 May 29. STAR Protoc. 2025. PMID: 40449004 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous