Development of a novel ultrasound-assisted headspace liquid-phase microextraction and its application to the analysis of chlorophenols in real aqueous samples
- PMID: 17765249
- DOI: 10.1016/j.chroma.2007.08.022
Development of a novel ultrasound-assisted headspace liquid-phase microextraction and its application to the analysis of chlorophenols in real aqueous samples
Abstract
A new sample pretreatment technique, ultrasound-assisted headspace liquid-phase microextraction was developed as mentioned in this paper. In the technique, the volatile analytes were headspace extracted into a small drop of solvent, which suspended on the bottom of a cone-shaped PCR tube instead of the needle tip of a microsyringe. More solvent could be suspended in the PCR tube than microsyringe due to the larger interfacial tension, thus the analysis sensitivity was significantly improved with the increase of the extractant volume. Moreover, ultrasound-assisted extraction and independent controlling temperature of the extractant and the sample were performed to enhance the extraction efficiency. Following the extraction, the solvent-loaded sample was analyzed by high-performance liquid chromatography. Chlorophenols (2-chlorophenol, 2,4-dichlorophenol and 2,6-dichlorophenol) were chosen as model analytes to investigate the feasibility of the method. The experimental conditions related to the extraction efficiency were systematically studied. Under the optimum experimental conditions, the detection limit (S/N=3), intra- and inter-day RSD were 6 ng mL(-1), 4.6%, 3.9% for 2-chlorophenol, 12 ng mL(-1), 2.4%, 8.8% for 2,4-dichlorophenol and 23 ng mL(-1), 3.3%, 5.3% for 2,6-dichlorophenol, respectively. The proposed method was successfully applied to determine chlorophenols in real aqueous samples. Good recoveries ranging from 84.6% to 100.7% were obtained. In addition, the extraction efficiency of our method and the conventional headspace liquid-phase microextraction were compared; the extraction efficiency of the former was about 21 times higher than that of the latter. The results demonstrated that the proposed method is a promising sample pretreatment approach, its advantages over the conventional headspace liquid-phase microextraction include simple setup, ease of operation, rapidness, sensitivity, precision and no cross-contamination. The method is very suitable for the analysis of trace volatile and semivolatile pollutants in real aqueous sample.
Similar articles
-
Dispersive liquid-liquid microextraction based on solidification of floating organic droplet followed by high-performance liquid chromatography with ultraviolet detection and liquid chromatography-tandem mass spectrometry for the determination of triclosan and 2,4-dichlorophenol in water samples.J Chromatogr A. 2011 Jun 24;1218(25):3830-6. doi: 10.1016/j.chroma.2011.04.050. Epub 2011 Apr 28. J Chromatogr A. 2011. PMID: 21601213
-
Low-density solvent-based dispersive liquid-liquid microextraction combined with single-drop microextraction for the fast determination of chlorophenols in environmental water samples by high performance liquid chromatography-ultraviolet detection.J Chromatogr A. 2013 Mar 8;1280:9-15. doi: 10.1016/j.chroma.2013.01.023. Epub 2013 Jan 11. J Chromatogr A. 2013. PMID: 23375770
-
Development of an improved liquid phase microextraction technique and its application in the analysis of flumetsulam and its two analogous herbicides in soil.J Agric Food Chem. 2007 Nov 14;55(23):9351-6. doi: 10.1021/jf0718345. Epub 2007 Oct 23. J Agric Food Chem. 2007. PMID: 17953444
-
Stir bar sorptive extraction for trace analysis.J Chromatogr A. 2007 Jun 8;1152(1-2):54-69. doi: 10.1016/j.chroma.2007.01.032. Epub 2007 Jan 13. J Chromatogr A. 2007. PMID: 17239895 Review.
-
Solid drop based liquid-phase microextraction.J Chromatogr A. 2010 Apr 16;1217(16):2337-41. doi: 10.1016/j.chroma.2009.11.026. Epub 2009 Nov 13. J Chromatogr A. 2010. PMID: 19962710 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources