Variability of coronary venous anatomy in patients undergoing cardiac resynchronization therapy: a high-speed rotational venography study
- PMID: 17765613
- DOI: 10.1016/j.hrthm.2007.05.023
Variability of coronary venous anatomy in patients undergoing cardiac resynchronization therapy: a high-speed rotational venography study
Abstract
Background: Imaging the coronary venous (CV) tree to delineate the coronary sinus and its tributaries can facilitate electrophysiological procedures, such as cardiac resynchronization therapy (CRT) and catheter ablation. Venography also allows visualization of the left atrial (LA) veins, which may be a potential conduit for ablative or pacing strategies given their proximity to foci that can trigger atrial fibrillation.
Objective: The aim of this study was to provide a detailed description of CV anatomy using rotational venography in patients undergoing CRT.
Methods: Coronary sinus (CS) size and the presence, size, and angulation of its tributaries were determined from the analysis of rotational CV angiograms from 51 patients (age 68 +/- 11 years; n = 12 women) undergoing CRT.
Results: The CS, posterior veins, and lateral veins were identified in 100%, 76%, and 91% of patients. Lateral veins were less prevalent in patients with a history of lateral myocardial infarction than in patients without such a history (33% vs. 96%; P = .014). The diameters of the CS and its tributaries were fairly variable (7.3-18.9 mm for CS, 1.3-10.5 mm for CS tributaries). The CS was larger in men than in women and in cases of ischemic than in cases of nonischemic cardiomyopathy (all P <.05). The vein of Marshall, the most constant LA vein, was identified in 37 patients; its diameter is 1.7 +/- 0.5 mm, and its takeoff angle is 154 degrees +/- 15 degrees , making the vein potentially accessible for cannulation.
Conclusions: Differences in CV anatomy that are related to either gender or coronary artery disease could have important practical implications during the left ventricular lead implantation. The anatomical features of the vein of Marshall make it a feasible potential conduit for epicardial LA pacing.
Comment in
-
Left ventricular lead placement for cardiac resynchronization therapy: what you get is what you see!Heart Rhythm. 2007 Sep;4(9):1163-4. doi: 10.1016/j.hrthm.2007.06.001. Epub 2007 Jun 8. Heart Rhythm. 2007. PMID: 17765614 No abstract available.
Similar articles
-
Usefulness of high-speed rotational coronary venous angiography during cardiac resynchronization therapy.Am J Cardiol. 2007 Nov 15;100(10):1561-5. doi: 10.1016/j.amjcard.2007.06.062. Am J Cardiol. 2007. PMID: 17996520
-
Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography.J Am Coll Cardiol. 2006 Nov 7;48(9):1832-8. doi: 10.1016/j.jacc.2006.07.042. Epub 2006 Oct 17. J Am Coll Cardiol. 2006. PMID: 17084258
-
Multidetector cardiac tomography: a useful tool before cardiac resynchronization therapy.Cardiol J. 2015;22(5):590-6. doi: 10.5603/CJ.a2015.0011. Epub 2015 Mar 3. Cardiol J. 2015. PMID: 25733321
-
Angiographic Anatomy of the Left Coronary Veins: Beyond Conventional Cardiac Resynchronization Therapy.Curr Cardiol Rep. 2025 Feb 19;27(1):58. doi: 10.1007/s11886-025-02204-z. Curr Cardiol Rep. 2025. PMID: 39969647 Free PMC article. Review.
-
The venous drainage of the human myocardium.Adv Anat Embryol Cell Biol. 2003;168:I-VIII, 1-104. doi: 10.1007/978-3-642-55623-4. Adv Anat Embryol Cell Biol. 2003. PMID: 12645157 Review.
Cited by
-
Right ventricular lead adjustment in cardiac resynchronization therapy and acute hemodynamic response: a pilot study.J Interv Card Electrophysiol. 2013 Apr;36(3):223-31. doi: 10.1007/s10840-012-9759-1. Epub 2012 Dec 21. J Interv Card Electrophysiol. 2013. PMID: 23263893
-
First-in-human noninvasive left ventricular ultrasound pacing: A potential screening tool for cardiac resynchronization therapy.Heart Rhythm O2. 2022 Oct 22;4(2):79-87. doi: 10.1016/j.hroo.2022.10.008. eCollection 2023 Feb. Heart Rhythm O2. 2022. PMID: 36873311 Free PMC article.
-
Visualisation of coronary venous anatomy by computed tomography angiography prior to cardiac resynchronisation therapy implantation.Neth Heart J. 2018 Sep;26(9):433-444. doi: 10.1007/s12471-018-1132-2. Neth Heart J. 2018. PMID: 30030750 Free PMC article.
-
Assessment of the coronary venous system using 256-slice computed tomography.PLoS One. 2014 Aug 4;9(8):e104246. doi: 10.1371/journal.pone.0104246. eCollection 2014. PLoS One. 2014. PMID: 25089900 Free PMC article.
-
Coronary venous system in cardiac computer tomography: Visualization, classification and role.World J Radiol. 2014 Jul 28;6(7):399-408. doi: 10.4329/wjr.v6.i7.399. World J Radiol. 2014. PMID: 25071880 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials