Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2008 Jul;67(1):78-84.
doi: 10.1016/j.ejrad.2007.07.014. Epub 2007 Sep 4.

Diagnostic value of 64-slice CT angiography in coronary artery disease: a systematic review

Affiliations
Meta-Analysis

Diagnostic value of 64-slice CT angiography in coronary artery disease: a systematic review

Zhonghua Sun et al. Eur J Radiol. 2008 Jul.

Abstract

Purpose: To perform a systematic review of the diagnostic value of 64-multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography.

Materials and methods: A search of PUBMED and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing 64-slice MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analysed at segment-, vessel- and patient-based assessment.

Results: Fifteen studies met selection criteria and were included for analysis. Pooled sensitivity, specificity, positive predictive value and negative predictive value as well as 95% confidence interval (CI) were 97% (94 and 99%), 88% (79 and 97%), 94% (91 and 97%), and 95% (90 and 99%) for patient-based assessment; 92% (85 and 99%), 92% (85 and 99%), 78% (66 and 91%) and 98% (96 and 99%) for vessel-based assessment; 90% (85 and 94%), 96% (95 and 97%), 75%(68 and 82%) and 98% (98 and 99%) for segment-based assessment, respectively. No significant difference was found in the diagnostic accuracy of 64-slice CT in the detection of CAD when comparison was performed either among four main coronary arteries, or between proximal and middle or distal segments (p>0.05).

Conclusion: Our results showed that 64-slice CT angiography has a high-diagnostic value in the detection of CAD. Severe coronary artery calcification seems to be the major factor affecting the visualisation and assessment.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms