Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2007 Sep 6;357(10):987-99.
doi: 10.1056/NEJMoa054686.

Dronedarone for maintenance of sinus rhythm in atrial fibrillation or flutter

Affiliations
Free article
Randomized Controlled Trial

Dronedarone for maintenance of sinus rhythm in atrial fibrillation or flutter

Bramah N Singh et al. N Engl J Med. .
Free article

Abstract

Background: Amiodarone is effective in maintaining sinus rhythm in atrial fibrillation but is associated with potentially serious toxic effects. Dronedarone is a new antiarrhythmic agent pharmacologically related to amiodarone but developed to reduce the risk of side effects.

Methods: In two identical multicenter, double-blind, randomized trials, one conducted in Europe (ClinicalTrials.gov number, NCT00259428 [ClinicalTrials.gov] ) and one conducted in the United States, Canada, Australia, South Africa, and Argentina (termed the non-European trial, NCT00259376 [ClinicalTrials.gov] ), we evaluated the efficacy of dronedarone, with 828 patients receiving 400 mg of the drug twice daily and 409 patients receiving placebo. Rhythm was monitored transtelephonically on days 2, 3, and 5; at 3, 5, 7, and 10 months; during recurrence of arrhythmia; and at nine scheduled visits during a 12-month period. The primary end point was the time to the first recurrence of atrial fibrillation or flutter.

Results: In the European trial, the median times to the recurrence of arrhythmia were 41 days in the placebo group and 96 days in the dronedarone group (P=0.01). The corresponding durations in the non-European trial were 59 and 158 days (P=0.002). At the recurrence of arrhythmia in the European trial, the mean (+/-SD) ventricular rate was 117.5+/-29.1 beats per minute in the placebo group and 102.3+/-24.7 beats per minute in the dronedarone group (P<0.001); the corresponding rates in the non-European trial were 116.6+/-31.9 and 104.6+/-27.1 beats per minute (P<0.001). Rates of pulmonary toxic effects and of thyroid and liver dysfunction were not significantly increased in the dronedarone group.

Conclusions: Dronedarone was significantly more effective than placebo in maintaining sinus rhythm and in reducing the ventricular rate during recurrence of arrhythmia.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

Associated data