Spatio-temporal analysis of molecular delivery through the blood-brain barrier using focused ultrasound
- PMID: 17804879
- DOI: 10.1088/0031-9155/52/18/004
Spatio-temporal analysis of molecular delivery through the blood-brain barrier using focused ultrasound
Abstract
The deposition of gadolinium through ultrasound-induced blood-brain barrier (BBB) openings in the murine hippocampus was investigated. First, wave propagation simulations through the intact mouse skull revealed minimal beam distortion while thermal deposition simulations, at the same sonication parameters used to induce BBB opening in vivo, revealed temperature increases lower than 0.5 degrees C. The simulation results were validated experimentally in ex vivo skulls (m = 6) and in vitro tissue specimens. Then, in vivo mice (n = 9) were injected with microbubbles (Optison; 25-50 microl) and sonicated (frequency: 1.525 MHz, pressure amplitudes: 0.5-1.1 MPa, burst duration: 20 ms, duty cycle: 20%, durations: 2-4 shots, 30 s per shot, 30 s interval) at the left hippocampus, through intact skin and skull. Sequential, high-resolution, T1-weighted MRI (9.4 Tesla, in-plane resolution: 75 microm, scan time: 45-180 min) with gadolinium (Omniscan; 0.5 ml) injected intraperitoneally revealed a threshold of the BBB opening at 0.67 MPa and BBB closing within 28 h from opening. The contrast-enhancement area and gadolinium deposition path were monitored over time and the influence of vessel density, size and location was determined. Sonicated arteries, or their immediate surroundings, depicted greater contrast enhancement than sonicated homogeneous brain tissue regions. In conclusion, gadolinium was delivered through a transiently opened BBB and contained to a specific brain region (i.e., the hippocampus) using a single-element focused ultrasound transducer. It was also found that the amount of gadolinium deposited in the hippocampal region increased with the acoustic pressure and that the spatial distribution of the BBB opening was determined not only by the ultrasound beam, but also by the vasculature of the targeted brain region.
Similar articles
-
Noninvasive and transient blood-brain barrier opening in the hippocampus of Alzheimer's double transgenic mice using focused ultrasound.Ultrason Imaging. 2008 Jul;30(3):189-200. doi: 10.1177/016173460803000304. Ultrason Imaging. 2008. PMID: 19149463 Free PMC article.
-
Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice.Ultrasound Med Biol. 2007 Jan;33(1):95-104. doi: 10.1016/j.ultrasmedbio.2006.07.018. Ultrasound Med Biol. 2007. PMID: 17189051
-
Efficiency of drug delivery enhanced by acoustic pressure during blood-brain barrier disruption induced by focused ultrasound.Int J Nanomedicine. 2012;7:2573-82. doi: 10.2147/IJN.S31675. Epub 2012 May 23. Int J Nanomedicine. 2012. PMID: 22679368 Free PMC article.
-
Ultrasound, microbubbles and the blood-brain barrier.Prog Biophys Mol Biol. 2007 Jan-Apr;93(1-3):354-62. doi: 10.1016/j.pbiomolbio.2006.07.019. Epub 2006 Aug 4. Prog Biophys Mol Biol. 2007. PMID: 16959303 Review.
-
Harnessing Ultrasound for Targeting Drug Delivery to the Brain and Breaching the Blood-Brain Tumour Barrier.Pharmaceutics. 2022 Oct 19;14(10):2231. doi: 10.3390/pharmaceutics14102231. Pharmaceutics. 2022. PMID: 36297666 Free PMC article. Review.
Cited by
-
Nanoparticle delivery enhancement with acoustically activated microbubbles.IEEE Trans Ultrason Ferroelectr Freq Control. 2013 Jan;60(1):65-77. doi: 10.1109/TUFFC.2013.2538. IEEE Trans Ultrason Ferroelectr Freq Control. 2013. PMID: 23287914 Free PMC article. Review.
-
Microbubble-size dependence of focused ultrasound-induced blood-brain barrier opening in mice in vivo.IEEE Trans Biomed Eng. 2010 Jan;57(1):145-54. doi: 10.1109/TBME.2009.2034533. Epub 2009 Oct 20. IEEE Trans Biomed Eng. 2010. PMID: 19846365 Free PMC article.
-
Determination of postexcitation thresholds for single ultrasound contrast agent microbubbles using double passive cavitation detection.J Acoust Soc Am. 2010 Jun;127(6):3449-55. doi: 10.1121/1.3373405. J Acoust Soc Am. 2010. PMID: 20550244 Free PMC article.
-
Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles.Phys Med Biol. 2018 Mar 15;63(6):065009. doi: 10.1088/1361-6560/aab05c. Phys Med Biol. 2018. PMID: 29457587 Free PMC article.
-
A new brain drug delivery strategy: focused ultrasound-enhanced intranasal drug delivery.PLoS One. 2014 Oct 3;9(10):e108880. doi: 10.1371/journal.pone.0108880. eCollection 2014. PLoS One. 2014. PMID: 25279463 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources