Performance of ultrasound based measurement of 3D displacement using a curvilinear probe for organ motion tracking
- PMID: 17804889
- DOI: 10.1088/0031-9155/52/18/014
Performance of ultrasound based measurement of 3D displacement using a curvilinear probe for organ motion tracking
Abstract
Three-dimensional (3D) soft tissue tracking is of interest for monitoring organ motion during therapy. Our goal is to assess the tracking performance of a curvilinear 3D ultrasound probe in terms of the accuracy and precision of measured displacements. The first aim was to examine the depth dependence of the tracking performance. This is of interest because the spatial resolution varies with distance from the elevational focus and because the curvilinear geometry of the transducer causes the spatial sampling frequency to decrease with depth. Our second aim was to assess tracking performance as a function of the spatial sampling setting (low, medium or high sampling). These settings are incorporated onto 3D ultrasound machines to allow the user to control the trade-off between spatial sampling and temporal resolution. Volume images of a speckle-producing phantom were acquired before and after the probe had been moved by a known displacement (1, 2 or 8 mm). This allowed us to assess the optimum performance of the tracking algorithm, in the absence of motion. 3D speckle tracking was performed using 3D cross-correlation and sub-voxel displacements were estimated. The tracking performance was found to be best for axial displacements and poorest for elevational displacements. In general, the performance decreased with depth, although the nature of the depth dependence was complex. Under certain conditions, the tracking performance was sufficient to be useful for monitoring organ motion. For example, at the highest sampling setting, for a 2 mm displacement, good accuracy and precision (an error and standard deviation of <0.4 mm) were observed at all depths and for all directions of displacement. The trade-off between spatial sampling, temporal resolution and size of the field of view (FOV) is discussed.
Similar articles
-
Analysis of motion tracking in echocardiographic image sequences: influence of system geometry and point-spread function.Ultrasonics. 2010 Mar;50(3):373-86. doi: 10.1016/j.ultras.2009.09.001. Epub 2009 Sep 19. Ultrasonics. 2010. PMID: 19837445
-
Sensorless freehand 3D ultrasound in real tissue: speckle decorrelation without fully developed speckle.Med Image Anal. 2006 Apr;10(2):137-49. doi: 10.1016/j.media.2005.08.001. Epub 2005 Sep 6. Med Image Anal. 2006. PMID: 16143560
-
Subsample interpolation strategies for sensorless freehand 3D ultrasound.Ultrasound Med Biol. 2006 Dec;32(12):1897-904. doi: 10.1016/j.ultrasmedbio.2006.06.027. Ultrasound Med Biol. 2006. PMID: 17169701
-
Freehand 3D ultrasound reconstruction algorithms--a review.Ultrasound Med Biol. 2007 Jul;33(7):991-1009. doi: 10.1016/j.ultrasmedbio.2007.02.015. Epub 2007 May 18. Ultrasound Med Biol. 2007. PMID: 17512655 Review.
-
Medical diagnostic applications and sources.Prog Biophys Mol Biol. 2007 Jan-Apr;93(1-3):84-110. doi: 10.1016/j.pbiomolbio.2006.07.004. Epub 2006 Aug 10. Prog Biophys Mol Biol. 2007. PMID: 16949652 Review.
Cited by
-
Robust model-based quantification of global ventricular torsion from spatially sparse three-dimensional time series data by orthogonal distance regression: evaluation in a canine animal model under different pacing regimes.Pacing Clin Electrophysiol. 2013 Jan;36(1):13-23. doi: 10.1111/j.1540-8159.2012.03496.x. Epub 2012 Aug 16. Pacing Clin Electrophysiol. 2013. PMID: 22897587 Free PMC article.
-
Systematic analysis of volumetric ultrasound parameters for markerless 4D motion tracking.Int J Comput Assist Radiol Surg. 2022 Nov;17(11):2131-2139. doi: 10.1007/s11548-022-02665-5. Epub 2022 May 21. Int J Comput Assist Radiol Surg. 2022. PMID: 35597846 Free PMC article.
-
[Ultrasound motion tracking for radiation therapy].Radiologe. 2015 Nov;55(11):984-91. doi: 10.1007/s00117-015-0027-0. Radiologe. 2015. PMID: 26438093 German.
-
Histotripsy cardiac therapy system integrated with real-time motion correction.Ultrasound Med Biol. 2013 Dec;39(12):2362-73. doi: 10.1016/j.ultrasmedbio.2013.08.004. Epub 2013 Sep 21. Ultrasound Med Biol. 2013. PMID: 24063958 Free PMC article.
-
The road to clinical use of high-intensity focused ultrasound for liver cancer: technical and clinical consensus.J Ther Ultrasound. 2013 Aug 1;1:13. doi: 10.1186/2050-5736-1-13. eCollection 2013. J Ther Ultrasound. 2013. PMID: 25512859 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources