Three-dimensional computed tomography cephalometric craniofacial analysis: experimental validation in vitro
- PMID: 17825530
- DOI: 10.1016/j.ijom.2007.05.022
Three-dimensional computed tomography cephalometric craniofacial analysis: experimental validation in vitro
Abstract
The development of three-dimensional (3D) cephalometric analysis is essential for the computer-assisted planning of orthognathic surgery. The aim of this study was to transform and adapt Delaire's two-dimensional cephalometric analysis into the third dimension; this transposition was then validated. The comparative advantage of using 3D computed tomography (CT) surface renderings over profile X-rays was analysed. Comparison was made of inter- and intra-observer reproducibility of the cephalometric measurements done on profile X-rays and on 3D CT surface renderings on the same 26 dry skulls. The accuracy was also tested of the measurements done on 3D CT surface renderings (ACRO 3D) in relation to those directly taken on dry skulls with the help of a 3D measuring instrument. Inter- and intra-observer reproducibility proved significantly superior (p<0.0001) following the 3D CT method. There were no significant differences in the accuracy of measurements between the ACRO 3D software and the 3D measuring instrument. The ACRO 3D software was confirmed as being a reliable tool for developing 3D CT cephalometric analyses. Further research may entail clinical validation of the 3D CT craniofacial cephalometric method of analysis.
Similar articles
-
Reproducibility of osseous landmarks used for computed tomography based three-dimensional cephalometric analyses.J Craniomaxillofac Surg. 2010 Apr;38(3):214-21. doi: 10.1016/j.jcms.2009.05.005. Epub 2009 Jul 1. J Craniomaxillofac Surg. 2010. PMID: 19574058
-
A comparison between 2D and 3D cephalometry on CBCT scans of human skulls.Int J Oral Maxillofac Surg. 2010 Feb;39(2):156-60. doi: 10.1016/j.ijom.2009.11.017. Epub 2009 Dec 30. Int J Oral Maxillofac Surg. 2010. PMID: 20044238
-
Three-dimensional fetal cephalometry: an evaluation of the reliability of cephalometric measurements based on three-dimensional CT reconstructions and on dry skulls of sheep fetuses.J Craniomaxillofac Surg. 2005 Aug;33(4):229-37. doi: 10.1016/j.jcms.2005.02.003. J Craniomaxillofac Surg. 2005. PMID: 15978824
-
Three-dimensional surface acquisition systems for the study of facial morphology and their application to maxillofacial surgery.Int J Med Robot. 2007 Jun;3(2):97-110. doi: 10.1002/rcs.141. Int J Med Robot. 2007. PMID: 17619242 Review.
-
[Three-dimensional imaging of the cranium and the central nervous system].Nihon Rinsho. 2004 Apr;62(4):661-7. Nihon Rinsho. 2004. PMID: 15106338 Review. Japanese.
Cited by
-
[Characteristics of mandible and mandibular dentition in patients with near-normal occlusion and different vertical facial skeletal types].Hua Xi Kou Qiang Yi Xue Za Zhi. 2017 Aug 1;35(4):403-407. doi: 10.7518/hxkq.2017.04.012. Hua Xi Kou Qiang Yi Xue Za Zhi. 2017. PMID: 28853508 Free PMC article. Chinese.
-
Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT.Imaging Sci Dent. 2012 Mar;42(1):25-33. doi: 10.5624/isd.2012.42.1.25. Epub 2012 Mar 22. Imaging Sci Dent. 2012. PMID: 22474645 Free PMC article.
-
Use of the orbito-occipital line as an alternative to the Frankfort line.Anat Cell Biol. 2020 Mar;53(1):21-26. doi: 10.5115/acb.19.136. Epub 2020 Feb 4. Anat Cell Biol. 2020. PMID: 32274245 Free PMC article.
-
New 3-dimensional cephalometric analysis for orthognathic surgery.J Oral Maxillofac Surg. 2011 Mar;69(3):606-22. doi: 10.1016/j.joms.2010.09.010. Epub 2011 Jan 22. J Oral Maxillofac Surg. 2011. PMID: 21257250 Free PMC article.
-
Use of an anatomical mid-sagittal plane for 3-dimensional cephalometry: A preliminary study.Imaging Sci Dent. 2019 Jun;49(2):159-169. doi: 10.5624/isd.2019.49.2.159. Epub 2019 Jun 24. Imaging Sci Dent. 2019. PMID: 31281793 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources