Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation
- PMID: 17826276
- DOI: 10.1016/j.arth.2006.11.014
Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation
Abstract
We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.
Similar articles
-
[Survival of dual mobility socket with a mean 17 years follow-up].Rev Chir Orthop Reparatrice Appar Mot. 2008 Feb;94(1):43-8. doi: 10.1016/j.rco.2007.10.011. Epub 2008 Feb 20. Rev Chir Orthop Reparatrice Appar Mot. 2008. PMID: 18342029 French.
-
[Results of the Evora dual mobility socket: five years follow-up].Rev Chir Orthop Reparatrice Appar Mot. 2008 Feb;94(1):37-42. doi: 10.1016/j.rco.2007.10.009. Epub 2008 Feb 1. Rev Chir Orthop Reparatrice Appar Mot. 2008. PMID: 18342028 French.
-
Reduction in early dislocation rate with large-diameter femoral heads in primary total hip arthroplasty.J Arthroplasty. 2007 Sep;22(6 Suppl 2):140-4. doi: 10.1016/j.arth.2007.04.019. Epub 2007 Jul 27. J Arthroplasty. 2007. PMID: 17823033
-
Unstable total hip arthroplasty: detailed overview.Instr Course Lect. 2001;50:265-74. Instr Course Lect. 2001. PMID: 11372323 Review.
-
Instability after total hip arthroplasty: treatment with large femoral heads vs constrained liners.J Arthroplasty. 2008 Oct;23(7 Suppl):59-63. doi: 10.1016/j.arth.2008.06.032. J Arthroplasty. 2008. PMID: 18922375 Review.
Cited by
-
Clinical Outcomes of Total Hip Arthroplasty With the Anterolateral Modified Watson-Jones Approach for Displaced Femoral Neck Fractures.Geriatr Orthop Surg Rehabil. 2022 Oct 15;13:21514593221134800. doi: 10.1177/21514593221134800. eCollection 2022. Geriatr Orthop Surg Rehabil. 2022. PMID: 36262694 Free PMC article.
-
Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips.Int Orthop. 2012 Mar;36(3):511-8. doi: 10.1007/s00264-011-1289-4. Epub 2011 Jun 23. Int Orthop. 2012. PMID: 21698430 Free PMC article.
-
A double mobility acetabular implant for primary hip arthroplasty in patients at high risk of dislocation.Ann R Coll Surg Engl. 2014 Nov;96(8):597-601. doi: 10.1308/003588414X14055925058391. Ann R Coll Surg Engl. 2014. PMID: 25350182 Free PMC article.
-
The use of a cemented dual mobility socket to treat recurrent dislocation.Clin Orthop Relat Res. 2010 Dec;468(12):3248-54. doi: 10.1007/s11999-010-1404-7. Clin Orthop Relat Res. 2010. PMID: 20532718 Free PMC article.
-
What are the causes for failures of primary hip arthroplasties in France?Clin Orthop Relat Res. 2013 Dec;471(12):3863-9. doi: 10.1007/s11999-013-2935-5. Clin Orthop Relat Res. 2013. PMID: 23529633 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical