Use of a turndown quadriceps tendon flap for rupture of the patellar tendon after total knee arthroplasty
- PMID: 17826289
- DOI: 10.1016/j.arth.2006.12.105
Use of a turndown quadriceps tendon flap for rupture of the patellar tendon after total knee arthroplasty
Abstract
Patellar tendon rupture is a devastating complication after total knee arthroplasty. The results of surgical treatment of this complication were discouraging in most of the reports. We describe a case of rupture of patellar tendon 7 weeks after total knee arthroplasty treated with a turndown quadriceps flap and circumferential wiring. Two years and 6 months after operation, the patient had no extension lag of the knee and knee flexion to 110 degrees .
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical