Influence of tissue preparation techniques on p53 expression in bronchial and bladder carcinomas, assessed by immunofluorescence staining and flow cytometry
- PMID: 1782831
- DOI: 10.1002/cyto.990120706
Influence of tissue preparation techniques on p53 expression in bronchial and bladder carcinomas, assessed by immunofluorescence staining and flow cytometry
Abstract
In a series of bronchial and bladder carcinomas, p53 protein expression was examined. Samples from formalin-fixed, paraffin-embedded tissue (routine-treated) were compared with parallel samples of fresh tissue and tissue fixed in paraformaldehyde and ethanol. The expression of p53 was measured by immunofluorescence staining and dual parameter flow cytometry, with simultaneous monitoring of DNA content. For each tumor, p53 fluorescence with different fixatives was expressed relative to fresh tissue. The p53 fluorescence signals were on average brighter from routine-treated tissue than from fresh tissue. The tissue fixed in paraformaldehyde showed no difference from fresh tissue. In the ethanol-fixed tissue, however, fluorescence signals were reduced by nearly 70%, and the fraction of detectable p53 positive cells in tumor tissue was reduced by more than 50%. This loss of fluorescence was probably due to a leakage of the antigen from nucleus to cytoplasm. Pepsin treatment did not influence p53 fluorescence. Within the same tumor, the S-phase fraction in p53 positive cells was significantly higher than in p53 negative cells (13.1 +/- 2.0% vs. 6.5 +/- 0.8%). This pattern was not influenced by formalin fixation or pepsin treatment. Our study demonstrates that in measuring a nuclear antigen, tissue handling may influence the results, and care should be taken to optimize the preparation procedure. Using the antibody PAb 1801, p53 expression measured in archival material is not reduced as compared to fresh tissue.
Similar articles
-
Flow cytometric measurement of p53 protein expression and DNA content in paraffin-embedded tissue from bronchial carcinomas.Cytometry. 1991;12(5):438-44. doi: 10.1002/cyto.990120509. Cytometry. 1991. PMID: 1935458
-
Fixation of mammalian cells for flow cytometric evaluation of DNA content and nuclear immunofluorescence.Cytometry. 1992;13(1):48-59. doi: 10.1002/cyto.990130109. Cytometry. 1992. PMID: 1372202
-
Comparison of flow and image cytometry for DNA content analysis of fresh and formalin-fixed, paraffin-embedded tissue in breast carcinoma.Cytometry. 1995 Sep 15;22(3):181-9. doi: 10.1002/cyto.990220305. Cytometry. 1995. PMID: 8556949
-
The measurement of intracellular antigens and DNA by multiparametric flow cytometry.J Microsc. 1994 Oct;176(Pt 1):1-7. doi: 10.1111/j.1365-2818.1994.tb03493.x. J Microsc. 1994. PMID: 7799424 Review.
-
Immunophenotyping using fixed cells.Methods Cell Biol. 1994;41:81-93. doi: 10.1016/s0091-679x(08)61710-0. Methods Cell Biol. 1994. PMID: 7532269 Review. No abstract available.