Early detection of Alzheimer's disease and related disorders (ADRD) is important, especially in primary care settings. We compared performances of two common screening tests, the Mini-Mental State Exam (MMSE) and Clock Drawing Test (CDT), with that of the MCI Screen ({MCIS}) in 254 patients over 65. None had previous diagnosis of ADRD, and 81% were asymptomatic by Functional Assessment Staging Test ({FAST}) (FAST=1). 215 patients completed all screening tests - 141 had >or= 1 abnormal result, 121/141 completed standardized diagnostic assessment, and the remaining 74/215 (34%) screened entirely normally and weren't further evaluated. Potential bias due to unevaluated cases was statistically adjusted. Among diagnosed cases: AD=43%, cerebrovascular disease=36%, other causes=21%. Bias-adjusted MCI prevalence for FAST stages 1 and 1-3 were 13.9-20.3% and 23.0-28.3%. Bias-adjusted results for the CDT, MMSE and MCIS were: clinical diagnosis validity (kappa statistic)={-0.02 (p=0.61), 0.06 (p=0.23), 0.92 (p< 0.0001)}; sensitivity={59%, 71%, 94%}; specificity={39%, 36%, 97%}; overall accuracy={54%, 62%, 96%}; positive predictive value={16%, 17%, 86%}; and negative predictive value={83%, 87%, 96%}. The MMSE and CDT were not valid for early detection, while the MCIS had high validity and accuracy in the primary care cohort.