Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2007 Nov-Dec;26(6):751-74.
doi: 10.1002/mas.20149.

Liquid chromatography combined with mass spectrometry for 13C isotopic analysis in life science research

Affiliations
Review

Liquid chromatography combined with mass spectrometry for 13C isotopic analysis in life science research

Jean-Philippe Godin et al. Mass Spectrom Rev. 2007 Nov-Dec.

Abstract

Among the different disciplines covered by mass spectrometry, measurement of (13)C/(12)C isotopic ratio crosses a large section of disciplines from a tool revealing the origin of compounds to more recent approaches such as metabolomics and proteomics. Isotope ratio mass spectrometry (IRMS) and molecular mass spectrometry (MS) are the two most mature techniques for (13)C isotopic analysis of compounds, respectively, for high and low-isotopic precision. For the sample introduction, the coupling of gas chromatography (GC) to either IRMS or MS is state of the art technique for targeted isotopic analysis of volatile analytes. However, liquid chromatography (LC) also needs to be considered as a tool for the sample introduction into IRMS or MS for (13)C isotopic analyses of non-volatile analytes at natural abundance as well as for (13)C-labeled compounds. This review presents the past and the current processes used to perform (13)C isotopic analysis in combination with LC. It gives particular attention to the combination of LC with IRMS which started in the 1990's with the moving wire transport, then subsequently moved to the chemical reaction interface (CRI) and was made commercially available in 2004 with the wet chemical oxidation interface (LC-IRMS). The LC-IRMS method development is also discussed in this review, including the possible approaches for increasing selectivity and efficiency, for example, using a 100% aqueous mobile phase for the LC separation. In addition, applications for measuring (13)C isotopic enrichments using atmospheric pressure LC-MS instruments with a quadrupole, a time-of-flight, and an ion trap analyzer are also discussed as well as a LC-ICPMS using a prototype instrument with two quadrupoles.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

Substances

LinkOut - more resources