Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Sep;98(3):175-85.
doi: 10.1016/S0022-3913(07)60053-5.

Coverage error of three conceptually different shade guide systems to vital unrestored dentition

Affiliations
Comparative Study

Coverage error of three conceptually different shade guide systems to vital unrestored dentition

Funda Bayindir et al. J Prosthet Dent. 2007 Sep.

Abstract

Statement of problem: It remains unclear which shade guide system is most representative of the shades found in the human dentition.

Purpose: The purpose of this study was to determine and to compare the coverage errors (CEs) of 3 different shades in a selected population.

Material and methods: The coverage errors of the following shade guide systems were evaluated to determine which shade guide system is most effective in producing the best visual shade match: (1) Vita Lumin, (2) Chromascop, (3) Vitapan 3D Master, and (4) a combination of the 3 shade guide systems. The spectral reflectance values of the central one ninth (1-mm diameter) of each shade tab (without a backing) were measured with a spectroradiometer and an external light source at wavelengths from 380 nm to 780 nm at 2-nm intervals. All spectral reflectance measurements were made using 0-degree observer and 45-degree illumination and then converted to CIE values. The color values of 359 anterior teeth were measured with the same protocol. The CEs for each of the 359 anterior teeth for each shade guide system, and with all 3 shade guide systems, were determined and averaged. Repeated measure ANOVA was used to evaluate the mean minimum CEs within-subject (shade guide system) and between-subject (age) difference as well as the interaction between these variables (alpha=.05). Then, a post hoc multiple comparison was performed using the Tukey-Kramer test.

Results: A significant difference (P<.001) was found among the mean minimum CEs of the 3 shade guide systems and their combination, but not between age groups (P=.384). An interaction was found between shade guide systems and age (P<.001). The Tukey-Kramer test revealed that the mean minimum CEs for Vita Lumin (5.39 DeltaE) and Chromoscop (5.28 DeltaE) shade guide systems were not significantly different from each other. However, the combination of all 3 shade guide systems (3.69 DeltaE) and Vitapan 3D Master (3.93 DeltaE) were significantly different from the Vita Lumin and Chromoscop shade guide system. The rankings of the shade guide systems within each age group were similar between the age groups.

Conclusions: The Vitapan 3D Master shade guide system resulted in the lowest coverage errors compared to the Vita Lumin or Chromascop shade guide systems. Coverage errors for the Vitapan 3D Master shade guide system did not differ significantly from the coverage errors when all 3 shade guide systems were combined.

PubMed Disclaimer

Figures

1
1
a* vs. b* for 359 anterior human teeth and average color of 3 shade guide systems (62 tabs).
2
2
L* vs. chroma for 359 anterior teeth of human subjects and average color of 3 shade guide systems (62 tabs).
3
3
Frequency of selection for Vita Lumin shade guide.
4
4
Frequency of selection for Chromoscop shade guide.
5
5
Frequency of selection for Vitapan 3D Master shade guide.
6
6
Frequency of selection for combination of all 3 guide systems: Chromoscop, Vita Lumin, and Vitapan 3D Master shade guides.

Comment in

References

    1. Goodkind RJ, Loupe MJ. Teaching of color in predoctoral and postdoctoral dental education in 1988. J Prosthet Dent. 1992;67:713–7. - PubMed
    1. Paravina RD, Powers JM, Fay RM. Dental color standards: shade tab arrangement. J Esthet Restor Dent. 2001;13:254–63. - PubMed
    1. Wee AG. Description of color, color replication process and esthetics. In: Rosenstiel SF, Land MF, Fujimoto J, editors. Contemporary fixed prosthodontics. 4. St. Louis: Mosby; 2006. p. 712.
    1. Okubo SR, Kanawati A, Richards MW, Childress S. Evaluation of visual and instrument shade matching. J Prosthet Dent. 1998;80:642–8. - PubMed
    1. Cal E, Sonugelen M, Guneri P, Kesercioglu A, Kose T. Application of a digital technique in evaluating the reliability of shade guides. J Oral Rehabil. 2004;31:483–91. - PubMed

Publication types