Study of two devices used to maintain normothermia in rats and mice during general anesthesia
- PMID: 17877326
Study of two devices used to maintain normothermia in rats and mice during general anesthesia
Abstract
Rodents are very susceptible to hypothermia during anesthetic events because of their high body surface-to-mass ratio. This study examined the effectiveness of 2 heating devices, a heatpad and a circulating hot-water blanket, during 60 min of isoflurane general anesthesia in rats and mice (n = 6 per treatment). In addition, 1 control group of animals for each species was anesthetized with no heat source (n = 6). Both devices carried minimal risk of causing thermal burns or hyperthermia. Rats on the circulating water blanket showed a slight decrease (0.11 +/- 0.19 degrees C) from the initial (time 0) body temperature (mean +/- standard error), whereas the heatpad was associated with a significant increase (0.96 +/- 0.10 degrees C). Mice on the circulating water blanket showed a significant decrease (0.46 +/- 0.05 degrees C) in body temperature. The trend in mice on the heatpad was similar to that in rats, with a significant increase (0.94 +/- 0.13 degrees C) from the body temperature at time 0. Although statistically significant, these deviations from baseline body temperature were not considered physiologically relevant. In comparison, body temperatures decreased significantly in rats and mice (4.42 +/- 0.60 and 9.90 +/- 0.35 degrees C, respectively) with no heat source. Both heating devices were safe and effective, but the low cost, ease of maintenance, and portability of the heatpad may make it a more desirable choice in some facilities.
Similar articles
-
Comparison of heating devices for maintaining body temperature in anesthetized laboratory rabbits (Oryctolagus cuniculus).J Am Assoc Lab Anim Sci. 2007 May;46(3):61-3. J Am Assoc Lab Anim Sci. 2007. PMID: 17487956
-
A comparison of a forced-air warming system to traditional thermal support for rodent microenvironments.Lab Anim. 2004 Jan;38(1):55-63. doi: 10.1258/00236770460734407. Lab Anim. 2004. PMID: 14979989
-
[Air-convection heater for abdominal surgery. Study of the relation between surgical time and the efficacy of body temperature maintenance].Rev Esp Anestesiol Reanim. 1997 Feb;44(2):47-51. Rev Esp Anestesiol Reanim. 1997. PMID: 9148355 Clinical Trial. Spanish.
-
[Non-therapeutic intraoperative hypothermia: prevention and treatment (part II)].Rev Esp Anestesiol Reanim. 2003 Apr;50(4):197-208. Rev Esp Anestesiol Reanim. 2003. PMID: 12825309 Review. Spanish.
-
[Amino acid administration counteracts hypothermia during anesthesia].Lakartidningen. 2001 Apr 4;98(14):1664-9. Lakartidningen. 2001. PMID: 11379167 Review. Swedish.
Cited by
-
Optimizing Mouse Surgery with Online Rectal Temperature Monitoring and Preoperative Heat Supply. Effects on Post-Ischemic Acute Kidney Injury.PLoS One. 2016 Feb 18;11(2):e0149489. doi: 10.1371/journal.pone.0149489. eCollection 2016. PLoS One. 2016. PMID: 26890071 Free PMC article.
-
Comparison of Aqueous and Alcohol-based Agents for Presurgical Skin Preparation Methods in Mice.J Am Assoc Lab Anim Sci. 2018 Jul 1;57(4):401-414. doi: 10.30802/AALAS-JAALAS-17-000128. Epub 2018 Jul 3. J Am Assoc Lab Anim Sci. 2018. PMID: 29970215 Free PMC article.
-
"Point of no return" in unilateral renal ischemia reperfusion injury in mice.J Biomed Sci. 2020 Feb 14;27(1):34. doi: 10.1186/s12929-020-0623-9. J Biomed Sci. 2020. PMID: 32059667 Free PMC article.
-
Reporting Data on Auditory Brainstem Responses (ABR) in Rats: Recommendations Based on Review of Experimental Protocols and Literature.Brain Sci. 2021 Nov 30;11(12):1596. doi: 10.3390/brainsci11121596. Brain Sci. 2021. PMID: 34942898 Free PMC article.
-
Use of Air-activated Thermal Devices during Recovery after Surgery in Mice.J Am Assoc Lab Anim Sci. 2018 Jul 1;57(4):392-400. doi: 10.30802/AALAS-JAALAS-17-000077. Epub 2018 Jun 22. J Am Assoc Lab Anim Sci. 2018. PMID: 29933764 Free PMC article.