. 2008 Mar;12(1):69-75.
doi: 10.1007/s11325-007-0130-1.

Effect of an intra-oral nasal dilation appliance on 3-D nasal airway morphology in adults

Affiliations

Effect of an intra-oral nasal dilation appliance on 3-D nasal airway morphology in adults

G Dave Singh et al. Sleep Breath. 2008 Mar.

Abstract

To determine the effects of a nasal dilation appliance on 3-D nasopharyngeal airway patency. The sample comprised 187 adults (98 males, 89 females) with a history of sleep-disordered breathing. Acoustic rhinometry readings were taken from all patients before and after the intra-oral placement of a nasal dilation appliance (OASYS). The mean left and right nasopharyngeal airways were reconstructed in 3-D, and the data from the right and left nostrils were subjected to principal components analysis (PCA) and finite-element scaling analysis (FESA). Comparing the pre- and post-treatment 3-D mean, left nasopharyngeal airways using PCA, the first two eigenvalues accounted for 96% of the total shape change, and statistical differences were found (p < 0.01). Similarly, for the right side, significant differences were detected between the mean pre- and post-treatment 3-D nasopharyngeal airways (p < 0.01) using PCA. Using FESA to quantify and localize changes after the placement of the nasal dilation appliance, the 3-D mean, normalized, left nasopharyngeal airway was found to be 14% wider in the anterior nasal valve region and 28% wider in the distal regions, while the 3-D mean, normalized, right nasopharyngeal airway was 13% wider in the anterior nasal valve region and 27% wider further distally. The use of an intra-oral nasal dilation appliance may be useful in the management of nasopharyngeal conditions, such as snoring, upper airway resistance syndrome, sleep-disordered breathing, and obstructive sleep apnea, especially in cases where nasal obstruction is demonstrable.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. Facial Plast Surg Clin North Am. 2004 Nov;12(4):397-405, v - PubMed
    1. Med Sci Monit. 2004 Jul;10(7):CR431-8 - PubMed
    1. J Appl Physiol (1985). 2000 Sep;89(3):1013-21 - PubMed
    1. Arch Facial Plast Surg. 2005 Jan-Feb;7(1):45-50 - PubMed
    1. Sleep Breath. 2007 Dec;11(4):209-16 - PubMed

MeSH terms

LinkOut - more resources