[Needle-free injection--science fiction or comeback of an almost forgotten drug delivery system?]
- PMID: 17879809
[Needle-free injection--science fiction or comeback of an almost forgotten drug delivery system?]
Abstract
The first to create a "needle-free injector" was the American anesthetist Robert A. Hingson, 65 year ago. Since that time those devices underwent a changeful history. In 1986 an outbreak of hepatitis B among patients receiving injections from a needle-free multiple-use-nozzle injector was documented and related to the use of the injector device. Due to such risk of transmission of infection with these reusable devices, their application has been restricted. In 1998 the WHO recommended that only conventional needles and syringes should be used for immunization until safe needle-free injectors are identified through independent safety testing. Since needle-free injection has shown numerous advantages in comparison to conventional injection, new systems were developed that combine the advantages of needle-free injection with sufficient safety in mass vaccination programs. As an alternative to this early injector type, the disposable-cartridge injectors were developed. The newest research field in the area of the needle-free injection systems opened with the development of powder injectors, in which the drug preparation is no longer a suspension or solution, but a powdered solid. This injector type using powder formulations shows a number of advantages in comparison with the conventional needle/syringe injection technique as well as towards the liquid jet injectors. Due to this new kind of injectors the comeback of the needle-free injection technique in large-scale vaccination programs of the WHO seems reasonable and within reach.
Similar articles
-
[Cost of tetanus toxoid injection using a jet-injector (Imule) in collective immunization in Senegal: comparison with injection using a syringe and resterilizable needle].Sante. 1999 Sep-Oct;9(5):319-26. Sante. 1999. PMID: 10657777 French.
-
Reducing the risk of unsafe injections in immunization programmes: financial and operational implications of various injection technologies.Bull World Health Organ. 1995;73(4):531-40. Bull World Health Organ. 1995. PMID: 7554027 Free PMC article.
-
Preventing contamination between injections with multiple-use nozzle needle-free injectors: a safety trial.Vaccine. 2008 Mar 4;26(10):1344-52. doi: 10.1016/j.vaccine.2007.12.041. Epub 2008 Jan 18. Vaccine. 2008. PMID: 18272265 Clinical Trial.
-
Needle-free vaccine delivery.Adv Drug Deliv Rev. 2006 Apr 20;58(1):68-89. doi: 10.1016/j.addr.2005.12.003. Epub 2006 Mar 24. Adv Drug Deliv Rev. 2006. PMID: 16564111 Review.
-
Jet injection devices for the needle-free administration of compounds, vaccines, and other agents.Int J Pharm Compd. 2013 Jul-Aug;17(4):270-80. Int J Pharm Compd. 2013. PMID: 24261141 Review.
Cited by
-
A Needle-Free Jet Injection System for Controlled Release and Repeated Biopharmaceutical Delivery.Pharmaceutics. 2021 Oct 22;13(11):1770. doi: 10.3390/pharmaceutics13111770. Pharmaceutics. 2021. PMID: 34834185 Free PMC article.
-
Minipigs as an animal model for dermal vaccine delivery.Comp Med. 2014 Feb;64(1):50-4. Comp Med. 2014. PMID: 24512961 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical
Research Materials