Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Sep;61(3):460-8; discussion 468-9.
doi: 10.1227/01.NEU.0000290890.62201.A9.

Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up

Affiliations
Comparative Study

Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up

Alessandra Biondi et al. Neurosurgery. 2007 Sep.

Abstract

Objective: To evaluate the midterm results of intracranial stent-assisted coil embolization in the treatment of wide-necked cerebral aneurysms and to assess the efficacy of various strategies used in stent deployment.

Methods: A retrospective study of 42 patients with 46 wide-necked cerebral aneurysms enrolled in a prospective single-center registry of patients treated with a Neuroform stent (Boston Scientific/Target, Fremont, CA), a flexible self-expanding nitinol stent, was performed. Twenty-seven of 46 aneurysms were unruptured aneurysms, 14 were recanalized aneurysms, and five were acutely ruptured. Thirty-nine aneurysms were located in the anterior and seven in the posterior circulation. Mean aneurysm size was 9.8 mm. Stenting before coiling was performed in 13 of 45 aneurysms (29%), coiling before stenting in 27 of 45 aneurysms (60%), and stenting alone in five of 45 aneurysms (11%). The balloon remodeling technique for coiling before stenting was performed in 77% of patients. Angiographic and clinical follow up was available in 31 patients with 33 aneurysms and ranged from 3 to 24 months.

Results: Neuroform stenting was attempted in 46 wide-necked aneurysms (42 patients). Forty-nine stent sessions were performed, including three poststent retreatments. In 46 of 49 sessions (94%), successful deployment of 47 stents for 45 aneurysms was obtained. In 40 aneurysms treated with stent-assisted coiling, angiographic results showed 14 (35%) aneurysm occlusions, 18 (45%) neck remnants, and eight (20%) residual aneurysms. In five recanalized aneurysms treated with stenting alone, no changes were observed in four (80%) aneurysms and one (20%) neck remnant reduced in size. At angiographic follow-up in 30 aneurysms treated with stent-assisted coiling, there were 17 (57%) aneurysm occlusions, seven (23%) neck remnants, and six (20%) residual aneurysms. In three recanalized aneurysms treated with stent alone, two (67%) neck remnants remained unchanged and one (33%) neck remnant decreased in size. Procedural morbidity was observed in two of 42 patients (4.8%) and one patient died. On clinical follow-up, the modified Rankin Scale score was 0 in 27 patients (87%), 1 in three patients (10%), and 2 (3%) in one patient. No aneurysm bled during the follow-up period.

Conclusion: These results indicate that Neuroform stent-assisted coil embolization is a safe and effective technique in the treatment of wide-necked cerebral aneurysms. Further studies are needed to evaluate the long-term durability of stent-assisted aneurysm occlusion and tolerance to the stent.

PubMed Disclaimer

Publication types

LinkOut - more resources