Soft and intermediate plaques in coronary arteries: how accurately can we measure CT attenuation using 64-MDCT?
- PMID: 17885074
- DOI: 10.2214/AJR.07.2296
Soft and intermediate plaques in coronary arteries: how accurately can we measure CT attenuation using 64-MDCT?
Abstract
Objective: The objective of this study was to validate the accuracy of 64-MDCT densitometry of soft and intermediate plaques.
Materials and methods: Acrylonitrile-butadiene-styrene resin (47 H) and acrylic (110 H) were used to simulate soft and intermediate plaques, respectively, in coronary artery models (diameters of 3 and 4 mm). The variable parameters were heart rate (50, 65, 80, and 95 beats per minute), reconstruction algorithm (half and segmentation), coronary artery enhancement (150, 250, 350, and 450 H), CT densitometry site (arterial lumen or center), shape of plaque (D-shaped, centric, and eccentric), and level of stenosis due to plaque (25%, 50%, and 75% of arterial diameter). Measured CT attenuation values of soft and intermediate plaques were compared for different combinations of parameters. Repeated measures analysis of variance, Wilcoxon's signed rank, Mann-Whitney U, and Kruskal-Wallis tests were used for statistical analyses.
Results: For measuring soft plaque, CT densitometry was accurate at low heart rates with the use of a half reconstruction algorithm (p < 0.01) on intracoronary artery enhancement of 250 H (p < 0.01). For both soft and intermediate plaques, the densitometry measurements near the arterial lumen were overestimated and higher than those at the center (p < 0.01). For plaques that were 50% or more of the arterial diameter, accurate CT densitometry was possible.
Conclusion: Coronary artery enhancement has a significant impact on 64-MDCT densitometry measurements of coronary artery plaques, especially of soft plaques. A large plaque size, densitometry performed not near the arterial lumen but at the center of the plaque, intracoronary enhancement of 250 H, and a low heart rate increase the accuracy of plaque densitometry.
Similar articles
-
Radiation dose, image quality, stenosis measurement, and CT densitometry using ECG-triggered coronary 64-MDCT angiography: a phantom study.AJR Am J Roentgenol. 2008 Feb;190(2):315-20. doi: 10.2214/AJR.07.2191. AJR Am J Roentgenol. 2008. PMID: 18212215
-
Measuring noncalcified coronary atherosclerotic plaque using voxel analysis with MDCT angiography: a pilot clinical study.AJR Am J Roentgenol. 2008 Jun;190(6):1553-60. doi: 10.2214/AJR.07.2988. AJR Am J Roentgenol. 2008. PMID: 18492906
-
Quantification of coronary artery stenosis with high-resolution CT in comparison with histopathology in an ex vivo study.Eur J Radiol. 2013 Feb;82(2):264-9. doi: 10.1016/j.ejrad.2012.09.021. Epub 2012 Oct 29. Eur J Radiol. 2013. PMID: 23116807
-
Computed tomography for detecting coronary artery plaques: a meta-analysis.Atherosclerosis. 2011 Dec;219(2):603-9. doi: 10.1016/j.atherosclerosis.2011.08.022. Epub 2011 Aug 22. Atherosclerosis. 2011. PMID: 21920524 Review.
-
Cardiac CT for CAD. Do we still need angiography?J Cardiovasc Surg (Torino). 2009 Feb;50(1):7-17. J Cardiovasc Surg (Torino). 2009. PMID: 19179986 Review.
Cited by
-
Correction of lumen contrast-enhancement influence on non-calcified coronary atherosclerotic plaque quantification on CT.Int J Cardiovasc Imaging. 2015 Feb;31(2):429-36. doi: 10.1007/s10554-014-0554-1. Epub 2014 Oct 18. Int J Cardiovasc Imaging. 2015. PMID: 25326412
-
An early investigation of ytterbium nanocolloids for selective and quantitative "multicolor" spectral CT imaging.ACS Nano. 2012 Apr 24;6(4):3364-70. doi: 10.1021/nn300392x. Epub 2012 Mar 8. ACS Nano. 2012. PMID: 22385324 Free PMC article.
-
Standardized volumetric plaque quantification and characterization from coronary CT angiography: a head-to-head comparison with invasive intravascular ultrasound.Eur Radiol. 2019 Nov;29(11):6129-6139. doi: 10.1007/s00330-019-06219-3. Epub 2019 Apr 26. Eur Radiol. 2019. PMID: 31028446 Free PMC article.
-
Detecting vascular biosignatures with a colloidal, radio-opaque polymeric nanoparticle.J Am Chem Soc. 2009 Oct 28;131(42):15522-7. doi: 10.1021/ja906797z. J Am Chem Soc. 2009. PMID: 19795893 Free PMC article.
-
Novel contrast-injection protocol for coronary computed tomographic angiography: contrast-injection protocol customized according to the patient's time-attenuation response.Heart Vessels. 2014 Mar;29(2):149-55. doi: 10.1007/s00380-013-0338-x. Epub 2013 Mar 20. Heart Vessels. 2014. PMID: 23512260 Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical