Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Oct;56(Pt 10):1350-1355.
doi: 10.1099/jmm.0.47220-0.

Multiplex PCR for direct identification of Campylobacter spp. in human and chicken stools

Affiliations
Comparative Study

Multiplex PCR for direct identification of Campylobacter spp. in human and chicken stools

Aisha Al Amri et al. J Med Microbiol. 2007 Oct.

Abstract

Differentiation between Campylobacter jejuni and Campylobacter coli is problematic in clinical specimens due to fastidious growth requirements and limited biochemical tests. This study describes a rapid, multiplex PCR protocol for the direct detection and differentiation of C. jejuni and C. coli in stools. An evaluation was carried out of this multiplex protocol based on the detection of cadF (genus specific), and hipO (C. jejuni) and asp (C. coli) genes, using stool from patients with Campylobacter enteritis and chicken. Protocol sensitivity was assessed and specificity determined using a panel of enteric bacteria, and evaluation of 30 diarrhoeic stool specimens culture negative for Campylobacter. Of the 114 specimens (54 human and 60 chicken) evaluated by the protocol, 70 (61.4 %) were identified as C. jejuni, 35 (30.7 %) as C. coli and 9 (7.9 %) as a mixed infection/colonization with both species. All mixed infections were identified as C. jejuni by culture. Among the stool specimens that were culture negative for Campylobacter, two (6.7 %) were C. jejuni positive by multiplex PCR. The protocol sensitivity limit was 0.015-0.016 ng C. jejuni and C. coli DNA mul(-1) in the specimen. There was no cross-reaction with the reference strains assessed. Comparison of hippurate test and multiplex PCR demonstrated 17 isolates with false-positive hippurate enzymic activity and 7 with false-negative activity. This rapid protocol (turnaround time 6 h) is highly sensitive and specific for direct evaluation of stool for these pathogens. It has significant application for routine clinical diagnostic and epidemiological purposes.

PubMed Disclaimer

Publication types

MeSH terms

Substances