Abstract
Within the past 2 decades, the number of CT examinations performed has increased almost 10-fold. This is in large part due to advances in multidetector-row CT technology, which now allows faster image acquisition and improved isotropic imaging. The increased use, along with multidetector technique, has led to a significantly increased radiation dose to the patient from CT studies. This places increased responsibility on the radiologist to ensure that CT examinations are indicated and that the "as low as reasonably achievable" concept is adhered to. Neuroradiologists are familiar with factors that affect patient dose such as pitch, milliamperes, kilovolt peak (kVp), collimation, but with increasing attention being given to dose reduction, they are looking for additional ways to further reduce the radiation associated with their CT protocols. In response to increasing concern, CT manufacturers have developed dose-reduction tools, such as dose modulation, in which the tube current is adjusted along with the CT acquisition, according to patient's attenuation. This review will describe the available techniques for reducing dose associated with neuroradiologic CT imaging protocols.
Similar articles
-
Pediatric computed tomography imaging guideline.Acta Radiol. 2013 Nov;54(9):998-1006. doi: 10.1177/0284185113476020. Epub 2013 Apr 30. Acta Radiol. 2013. PMID: 23436822 Review.
-
Through the Looking Glass revisited: the need for more meaning and less drama in the reporting of dose and dose reduction in CT.Radiology. 2012 Oct;265(1):4-8. doi: 10.1148/radiol.12121145. Radiology. 2012. PMID: 22993216 No abstract available.
-
CT scan parameters and radiation dose: practical advice for radiologists.J Am Coll Radiol. 2013 Nov;10(11):840-6. doi: 10.1016/j.jacr.2013.05.032. J Am Coll Radiol. 2013. PMID: 24183553
-
CT dose reduction and dose management tools: overview of available options.Radiographics. 2006 Mar-Apr;26(2):503-12. doi: 10.1148/rg.262055138. Radiographics. 2006. PMID: 16549613 Review.
-
Raise the bar and lower the dose: current and future strategies for radiation dose reduction in head and neck imaging.AJNR Am J Neuroradiol. 2014 Apr;35(4):619-24. doi: 10.3174/ajnr.A3473. Epub 2013 Feb 28. AJNR Am J Neuroradiol. 2014. PMID: 23449649 Free PMC article. Review.
Cited by
-
Cerebral CTA with Low Tube Voltage and Low Contrast Material Volume for Detection of Intracranial Aneurysms.AJNR Am J Neuroradiol. 2016 Oct;37(10):1774-1780. doi: 10.3174/ajnr.A4803. Epub 2016 May 5. AJNR Am J Neuroradiol. 2016. PMID: 27151751 Free PMC article.
-
The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.AJNR Am J Neuroradiol. 2013 Jan;34(1):205-11. doi: 10.3174/ajnr.A3122. Epub 2012 May 24. AJNR Am J Neuroradiol. 2013. PMID: 22627796 Free PMC article.
-
Lowering the dose in head CT using adaptive statistical iterative reconstruction.AJNR Am J Neuroradiol. 2011 Oct;32(9):1578-82. doi: 10.3174/ajnr.A2585. Epub 2011 Aug 11. AJNR Am J Neuroradiol. 2011. PMID: 21835946 Free PMC article.
-
Model-based iterative reconstruction in paediatric head computed tomography: a pilot study on dose reduction in children.Pol J Radiol. 2021 Aug 30;86:e504-e510. doi: 10.5114/pjr.2021.108884. eCollection 2021. Pol J Radiol. 2021. PMID: 34567298 Free PMC article.
-
An education and training programme for radiological institutes: impact on the reduction of the CT radiation dose.Eur Radiol. 2011 Oct;21(10):2039-45. doi: 10.1007/s00330-011-2168-5. Epub 2011 May 31. Eur Radiol. 2011. PMID: 21626359
References
-
- Kalra MK, Maher MM, Toth TL, et al. Strategies for CT radiation dose optimization. Radiology 2004;230:619–28 - PubMed
-
- Berrington de Gonzalez A, Darby S. Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet 2004;363:345–51 - PubMed
-
- Imhof H, Schibany N, Ba-Ssalamah A, et al. Spiral CT and radiation dose. Eur J Radiol 2003;47:29–37 - PubMed
-
- Mayo JR, Aldrich J, Muller NL. Radiation exposure at chest CT: a statement of the Fleischner Society. Radiology 2003;228:15–21 - PubMed
-
- Wiest PW, Locken JA, Heintz PH, et al. CT scanning: a major source of radiation exposure. Semin Ultrasound CT MR 2002;23:402–10 - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous