Update in tonometry. Phosphene and rebound tonometries, self-tonometry and technologies for the future
- PMID: 17894294
Update in tonometry. Phosphene and rebound tonometries, self-tonometry and technologies for the future
Abstract
The Proview phosphene (eye-pressure) tonometer and the Rebound tonometer ICare are relatively new devices basically different from the Goldmann applanation tonometry (GAT). Both technologies will be presented in this review with respect to their principle, their technique, their advantages and limits, as well as their accuracy, the IOP measurements agreement with GAT, and the influence of central corneal thickness on the reliability of these measurements. Because the current data base for the interpretation of glaucoma disease course and its management are still relatively small, the development of a continuous, accurate, reliable and harmless monitoring of IOP over 24 hours is strongly desirable in the future. Approaches for self-tonometry and devices such as smart contact lenses which can take the IOP from the corneal surface have been developed with this goal. The future will probably confirm whether telemetric IOP monitoring with an implantable active microsystem allows a reliable IOP monitoring or not. In any case, active implants will open new and important perspectives in the diagnosis and the treatment of glaucomatous optic neuropathy.
Similar articles
-
[Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes].Klin Monbl Augenheilkd. 2006 Nov;223(11):899-903. doi: 10.1055/s-2006-927094. Klin Monbl Augenheilkd. 2006. PMID: 17131250 Clinical Trial. German.
-
Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers.Am J Ophthalmol. 2006 Aug;142(2):332-4. doi: 10.1016/j.ajo.2006.02.035. Am J Ophthalmol. 2006. PMID: 16876523
-
New ways to measure intraocular pressure.Curr Opin Ophthalmol. 2008 Mar;19(2):122-6. doi: 10.1097/ICU.0b013e3282f391ae. Curr Opin Ophthalmol. 2008. PMID: 18301285 Review.
-
The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice.Ophthalmology. 2004 Jun;111(6):1077-85. doi: 10.1016/j.ophtha.2003.09.036. Ophthalmology. 2004. PMID: 15177956
-
Measuring intraocular pressure-adjustments for corneal thickness and new technologies.Curr Opin Ophthalmol. 2006 Apr;17(2):115-9. doi: 10.1097/01.icu.0000193093.05927.a1. Curr Opin Ophthalmol. 2006. PMID: 16552245 Review.
Cited by
-
The blue arc entoptic phenomenon in glaucoma (an American ophthalmological thesis).Trans Am Ophthalmol Soc. 2013 Sep;111:46-55. Trans Am Ophthalmol Soc. 2013. PMID: 24167324 Free PMC article.
-
Self-tonometry in glaucoma.Graefes Arch Clin Exp Ophthalmol. 2010 Nov;248(11):1679-81. doi: 10.1007/s00417-010-1421-y. Epub 2010 Jun 8. Graefes Arch Clin Exp Ophthalmol. 2010. PMID: 20532552 Free PMC article. No abstract available.
-
Lab-on-a-Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics.Adv Mater. 2022 Jun;34(24):e2108389. doi: 10.1002/adma.202108389. Epub 2022 Apr 11. Adv Mater. 2022. PMID: 35130584 Free PMC article. Review.