Proximal isovelocity surface area should be routinely measured in evaluating mitral regurgitation: a core review
- PMID: 17898369
- DOI: 10.1213/01.ane.0000278084.35122.4e
Proximal isovelocity surface area should be routinely measured in evaluating mitral regurgitation: a core review
Abstract
The proximal isovelocity surface area (PISA) measurement, also known as the "flow convergence" method, can be used in echocardiography to estimate the area of an orifice through which blood flows. It has many applications, but this review focuses only on its use in the intraoperative evaluation of mitral regurgitation. In that setting, PISA provides a quantitative assessment of the severity of mitral regurgitation and it is useful in clinical decision-making in the operating room. In this review, I discuss the physical principles behind the PISA method, along with the various mathematical formulas used to calculate the effective mitral regurgitant orifice area, the regurgitant volume, and the regurgitant fraction. A step-by-step approach is presented and illustrated with graphic and video demonstrations. Finally, I will discuss the various limitations and technical considerations of PISA measurement in the operating room.
Comment in
-
CON: Proximal isovelocity surface area should not be measured routinely in all patients with mitral regurgitation.Anesth Analg. 2007 Oct;105(4):944-6. doi: 10.1213/01.ane.0000278524.33706.95. Anesth Analg. 2007. PMID: 17898370 No abstract available.
-
PRO: Proximal isovelocity surface area should be routinely measured in evaluating mitral regurgitation.Anesth Analg. 2007 Oct;105(4):947-8. doi: 10.1213/01.ane.0000278082.05309.a1. Anesth Analg. 2007. PMID: 17898371 No abstract available.
Similar articles
-
Comparison of orifice area by transthoracic three-dimensional Doppler echocardiography versus proximal isovelocity surface area (PISA) method for assessment of mitral regurgitation.Am J Cardiol. 2006 Jun 1;97(11):1630-7. doi: 10.1016/j.amjcard.2005.12.065. Epub 2006 Apr 19. Am J Cardiol. 2006. PMID: 16728228
-
[Calculation of the regurgitation fraction in mitral insufficiency by Doppler echocardiography using a study of the zone of flow convergence].Arch Mal Coeur Vaiss. 1997 Jan;90(1):17-25. Arch Mal Coeur Vaiss. 1997. PMID: 9137711 Review. French.
-
Reproducibility of proximal isovelocity surface area, vena contracta, and regurgitant jet area for assessment of mitral regurgitation severity.JACC Cardiovasc Imaging. 2010 Mar;3(3):235-43. doi: 10.1016/j.jcmg.2009.09.029. JACC Cardiovasc Imaging. 2010. PMID: 20223419
-
Geometry of the proximal isovelocity surface area in mitral regurgitation by 3-dimensional color Doppler echocardiography: difference between functional mitral regurgitation and prolapse regurgitation.Am Heart J. 2008 Feb;155(2):231-8. doi: 10.1016/j.ahj.2007.09.002. Epub 2007 Oct 25. Am Heart J. 2008. PMID: 18215591 Clinical Trial.
-
Current status of flow convergence for clinical applications: is it a leaning tower of "PISA"?J Am Coll Cardiol. 1996 Feb;27(2):504-9. doi: 10.1016/0735-1097(95)00486-6. J Am Coll Cardiol. 1996. PMID: 8557928 Review.
Cited by
-
The Right Ventricle-You May Forget it, but It Will Not Forget You.J Clin Med. 2020 Feb 5;9(2):432. doi: 10.3390/jcm9020432. J Clin Med. 2020. PMID: 32033368 Free PMC article. Review.
-
Clinical applications of artificial intelligence and machine learning in neurocardiology: a comprehensive review.Front Cardiovasc Med. 2025 Apr 3;12:1525966. doi: 10.3389/fcvm.2025.1525966. eCollection 2025. Front Cardiovasc Med. 2025. PMID: 40248254 Free PMC article. Review.
-
Evidence-based recommendations for PISA measurements in mitral regurgitation: systematic review, clinical and in-vitro study.Int J Cardiol. 2013 Sep 30;168(2):1220-8. doi: 10.1016/j.ijcard.2012.11.059. Epub 2012 Dec 11. Int J Cardiol. 2013. PMID: 23245796 Free PMC article.
-
Mechanics of the Tricuspid Valve-From Clinical Diagnosis/Treatment, In-Vivo and In-Vitro Investigations, to Patient-Specific Biomechanical Modeling.Bioengineering (Basel). 2019 May 22;6(2):47. doi: 10.3390/bioengineering6020047. Bioengineering (Basel). 2019. PMID: 31121881 Free PMC article. Review.
-
A novel fully automated method for mitral regurgitant orifice area quantification.Int J Cardiol. 2013 Jul 1;166(3):688-95. doi: 10.1016/j.ijcard.2011.11.104. Epub 2012 Jan 2. Int J Cardiol. 2013. PMID: 22217482 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources