Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Jan;18(1):61-74.
doi: 10.1007/s10895-007-0238-5. Epub 2007 Sep 25.

Second-derivative synchronous fluorometric method for the simultaneous determination of cinnarizine and domperidone in pharmaceutical preparations. Application to biological fluids

Affiliations
Comparative Study

Second-derivative synchronous fluorometric method for the simultaneous determination of cinnarizine and domperidone in pharmaceutical preparations. Application to biological fluids

M I Walash et al. J Fluoresc. 2008 Jan.

Abstract

A rapid, simple and highly sensitive second derivative synchronous fluorometric method has been developed for the simultaneous analysis of binary mixture of cinnarizine (CN) and domperidone (DOM). The method is based upon measurement of the native fluorescence of these drugs at Deltalambda=80 nm in aqueous methanol (50% V/V). The different experimental parameters affecting the native fluorescence of the studied drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the range of 0.1 to 1.3 microg mL(-1) and 0.1-3.0 microg mL(-1) for CN and DOM, respectively with lower detection limits of 0.017 and 5.77 x 10(-3) microg mL(-1) and quantification limits of 0.058 and 0.02 microg mL(-1) for CN and DOM. The proposed method was successfully applied for the determination of the studied compounds in synthetic mixtures and in commercial tablets. The results obtained were in good agreement with those obtained with reference methods. The high sensitivity attained by the synchronous fluorometric method allowed the determination of CN in real and spiked human plasma. The mean % recoveries in case of spiked human plasma (n=3) were 96.39+/-1.18 while that in real human plasma (n = 3) was 104.67+/-4.16.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Pharm Biomed Anal. 2002 May 15;28(3-4):711-9 - PubMed
    1. Spectrochim Acta A Mol Biomol Spectrosc. 2005 Feb;61(4):567-73 - PubMed
    1. Biomed Chromatogr. 2002 Aug;16(5):319-26 - PubMed
    1. J Fluoresc. 2006 Sep;16(5):713-21 - PubMed
    1. Farmaco. 2004 Sep;59(9):713-22 - PubMed

Publication types

LinkOut - more resources