Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals
- PMID: 17900844
- DOI: 10.1016/j.jpba.2007.08.018
Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals
Abstract
A review is presented on the state of the art of the chemiluminescence analysis of pharmaceuticals by the two most relevant automated controlled-flow methodologies--flow-injection analysis (FIA) and sequential-injection analysis (SIA). The current chemiluminometric applications of FIA and SIA in pharmaceutical analysis are discussed with special emphasis on the analytical figures of merit and sample matrix characteristics. The review involving 211 references and covering papers published between 2001 and 2006 is divided into several sections according to the fundamental types of chemiluminescence systems employed.
Similar articles
-
[Recent progress in flow-injection chemiluminescence for pharmaceutical analysis].Guang Pu Xue Yu Guang Pu Fen Xi. 2006 May;26(5):816-20. Guang Pu Xue Yu Guang Pu Fen Xi. 2006. PMID: 16883844 Review. Chinese.
-
Analytical applications of flow injection with chemiluminescence detection--a review.Luminescence. 2001 Jan-Feb;16(1):1-23. doi: 10.1002/bio.607. Luminescence. 2001. PMID: 11180653 Review.
-
[Amperometric detection in the determination of drugs by non-separating flow methods--flow injection analysis and sequential injection analysis].Ceska Slov Farm. 2001 May;50(3):107-12. Ceska Slov Farm. 2001. PMID: 11394017 Czech.
-
Flow injection-chemiluminescence determination of puerarin in pharmaceutical preparations.J Pharm Biomed Anal. 2004 Nov 15;36(3):587-92. doi: 10.1016/j.jpba.2004.07.036. J Pharm Biomed Anal. 2004. PMID: 15522534
-
Development of a sensitive flow-injection-chemiluminescence detection method for the determination of levodopa.Luminescence. 2008 Sep-Oct;23(5):327-32. doi: 10.1002/bio.1039. Luminescence. 2008. PMID: 18500694
Cited by
-
Transparent Cross-Flow Platform as Chemiluminescence Detection Cell in Cross Injection Analysis.Molecules. 2023 Jan 30;28(3):1316. doi: 10.3390/molecules28031316. Molecules. 2023. PMID: 36770983 Free PMC article.
-
Development of a multicommutated flow system with chemiluminometric detection for quantification of gentamicin in pharmaceuticals.J Autom Methods Manag Chem. 2010;2010:913207. doi: 10.1155/2010/913207. Epub 2010 Oct 13. J Autom Methods Manag Chem. 2010. PMID: 20981343 Free PMC article.
-
Optical flow-through sensor for the determination of norfloxacin based on emission of KMnO(4)-Na (2)SO (3)-Tb (3+) system.J Fluoresc. 2008 Sep;18(5):843-51. doi: 10.1007/s10895-008-0313-6. Epub 2008 Jan 17. J Fluoresc. 2008. PMID: 18205029
-
Investigation on the micelle-sensitized Ce(IV)-lornoxicam-Rh B chemiluminescence system and its application.J Fluoresc. 2012 Jan;22(1):529-35. doi: 10.1007/s10895-011-0987-z. Epub 2011 Oct 4. J Fluoresc. 2012. PMID: 21968509
-
Chemical Derivatization in Flow Analysis.Molecules. 2022 Feb 26;27(5):1563. doi: 10.3390/molecules27051563. Molecules. 2022. PMID: 35268664 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical