Miniaturization of environmental chemical assays in flowing systems: the lab-on-a-valve approach vis-à-vis lab-on-a-chip microfluidic devices
- PMID: 17903463
- DOI: 10.1016/j.aca.2007.02.035
Miniaturization of environmental chemical assays in flowing systems: the lab-on-a-valve approach vis-à-vis lab-on-a-chip microfluidic devices
Abstract
The analytical capabilities of the microminiaturized lab-on-a-valve (LOV) module integrated into a microsequential injection (muSI) fluidic system in terms of analytical chemical performance, microfluidic handling and on-line sample processing are compared to those of the micro total analysis systems (muTAS), also termed lab-on-a-chip (LOC). This paper illustrates, via selected representative examples, the potentials of the LOV scheme vis-à-vis LOC microdevices for environmental assays. By means of user-friendly programmable flow and the exploitation of the interplay between the thermodynamics and the kinetics of the chemical reactions at will, LOV allows accommodation of reactions which, at least at the present stage, are not feasible by application of microfluidic LOC systems. Thus, in LOV one may take full advantage of kinetic discriminations schemes, where even subtle differences in reactions are utilized for analytical purposes. Furthermore, it is also feasible to handle multi-step sequential reactions of divergent kinetics; to conduct multi-parametric determinations without manifold reconfiguration by utilization of the inherent open-architecture of the micromachined unit for implementation of peripheral modules and automated handling of a variety of reagents; and most importantly, it offers itself as a versatile front end to a plethora of detection schemes. Not the least, LOV is regarded as an emerging downscaled tool to overcome the dilemma of LOC microsystems to admit real-life samples. This is nurtured via its intrinsic flexibility for accommodation of sample pre-treatment schemes aimed at the on-line manipulation of complex samples. Thus, LOV is playing a prominent role in the environmental field, whenever the monitoring of trace level concentration of pollutants is pursued, because both matrix isolation and preconcentration of target analytes is most often imperative, or in fact necessary, prior to sample presentation to the detector.
Similar articles
-
Hyphenating multisyringe flow injection lab-on-valve analysis with atomic fluorescence spectrometry for on-line bead injection preconcentration and determination of trace levels of hydride-forming elements in environmental samples.Anal Chem. 2006 Dec 15;78(24):8290-8. doi: 10.1021/ac061278y. Anal Chem. 2006. PMID: 17165818
-
The miniaturization of bioanalytical assays and sample pretreatments by exploiting meso-fluidic lab-on-valve configurations: a review.Anal Chim Acta. 2007 Oct 29;602(2):173-80. doi: 10.1016/j.aca.2007.09.019. Epub 2007 Sep 16. Anal Chim Acta. 2007. PMID: 17933601 Review.
-
Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis.Anal Chem. 2006 Apr 15;78(8):2832-40. doi: 10.1021/ac052256z. Anal Chem. 2006. PMID: 16615800
-
Recent advances and future prospects of mesofluidic lab-on-a-valve platforms in analytical sciences--a critical review.Anal Chim Acta. 2012 Oct 31;750:3-15. doi: 10.1016/j.aca.2012.03.049. Epub 2012 Apr 5. Anal Chim Acta. 2012. PMID: 23062425
-
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications.Chem Soc Rev. 2010 Mar;39(3):1153-82. doi: 10.1039/b820557b. Epub 2010 Jan 25. Chem Soc Rev. 2010. PMID: 20179830 Review.
Cited by
-
Application of dispersive liquid-liquid microextraction and reversed phase-high performance liquid chromatography for the determination of two fungicides in environmental water samples.Int J Environ Anal Chem. 2010 Sep 15;90(11):845-855. doi: 10.1080/03067310903180468. Epub 2010 Aug 11. Int J Environ Anal Chem. 2010. PMID: 20862191 Free PMC article.
-
A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells.Biomed Eng Online. 2015 Apr 18;14:36. doi: 10.1186/s12938-015-0024-6. Biomed Eng Online. 2015. PMID: 25907197 Free PMC article.
-
Application of Vertical Electrodes in Microfluidic Channels for Impedance Analysis.Micromachines (Basel). 2016 May 25;7(6):96. doi: 10.3390/mi7060096. Micromachines (Basel). 2016. PMID: 30404271 Free PMC article.
-
Online Coupling of Lab-on-Valve Format to Amperometry Based on Polyvinylpyrrolidone-Doped Carbon Paste Electrode and Its Application to the Analysis of Morin.J Anal Methods Chem. 2012;2012:257109. doi: 10.1155/2012/257109. Epub 2012 Apr 5. J Anal Methods Chem. 2012. PMID: 22567551 Free PMC article.
-
Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones.Lab Chip. 2016 Mar 21;16(6):943-58. doi: 10.1039/c5lc01524c. Epub 2016 Feb 22. Lab Chip. 2016. PMID: 26899264 Free PMC article. Review.
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous