Planning in the IGRT context: closing the loop
- PMID: 17903704
- DOI: 10.1016/j.semradonc.2007.06.002
Planning in the IGRT context: closing the loop
Abstract
Technological developments in image-guided radiotherapy systems have introduced new considerations to the treatment-planning process. These include more rational assessment and reduction of treatment margins; adaptation of treatment plans according to information gathered as treatment progresses; and facilitation of treatments involving the delivery of large, highly focused doses of radiation to tumors. We examine the performance of different treatment-room image-guidance systems in terms of target position accuracy; such information is important for determining treatment margins and deciding on an appropriate correction strategy. Some clinical situations may warrant a modification to a patient's treatment plan part way through a course of treatment, such as tumor shrinkage in response to treatment and daily organ variation. We discuss the challenges and review proposed strategies for treatment-plan adaptation. Image guidance in combination with 3-dimensional conformal and intensity-modulated radiotherapy has provided the tools for clinical trials of single-dose and hypofractionated treatment as an alternative to standard fractionation. We discuss the clinical realization of this treatment paradigm in various disease sites.
Similar articles
-
A review of image-guided intensity-modulated radiotherapy for spinal tumors.Neurosurgery. 2007 Aug;61(2):226-35; discussion 235. doi: 10.1227/01.NEU.0000279970.10309.B5. Neurosurgery. 2007. PMID: 17762734 Review.
-
Helical tomotherapy. Experiences of the first 150 patients in Heidelberg.Strahlenther Onkol. 2008 Jan;184(1):8-14. doi: 10.1007/s00066-008-1778-6. Strahlenther Onkol. 2008. PMID: 18188517
-
Intensity-modulated radiation therapy dose prescription, recording, and delivery: patterns of variability among institutions and treatment planning systems.J Natl Cancer Inst. 2008 Mar 5;100(5):300-7. doi: 10.1093/jnci/djn020. Epub 2008 Feb 26. J Natl Cancer Inst. 2008. PMID: 18314476
-
Different styles of image-guided radiotherapy.Semin Radiat Oncol. 2007 Oct;17(4):258-67. doi: 10.1016/j.semradonc.2007.07.003. Semin Radiat Oncol. 2007. PMID: 17903703 Review.
-
[Present and future of the image guided radiotherapy (IGRT) and its applications in lung cancer treatment].Cancer Radiother. 2007 Jan-Feb;11(1-2):23-31. doi: 10.1016/j.canrad.2006.10.001. Epub 2006 Nov 17. Cancer Radiother. 2007. PMID: 17113331 Review. French.
Cited by
-
Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.Med Phys. 2017 Jun;44(6):2595-2612. doi: 10.1002/mp.12227. Epub 2017 Apr 20. Med Phys. 2017. PMID: 28317123 Free PMC article.
-
Analysis of intraprostatic therapeutic effects in prostate cancer patients using [(11)C]-choline pet/ct after external-beam radiation therapy.Curr Oncol. 2013 Apr;20(2):104-10. doi: 10.3747/co.20.1217. Curr Oncol. 2013. PMID: 23559873 Free PMC article.
-
Effect of computed tomography value error on dose calculation in adaptive radiotherapy with Elekta X-ray volume imaging cone beam computed tomography.J Appl Clin Med Phys. 2021 Sep;22(9):271-279. doi: 10.1002/acm2.13384. Epub 2021 Aug 10. J Appl Clin Med Phys. 2021. PMID: 34375008 Free PMC article.
-
Clinical evaluation of positioning verification using digital tomosynthesis and bony anatomy and soft tissues for prostate image-guided radiotherapy.Int J Radiat Oncol Biol Phys. 2009 Jan 1;73(1):296-305. doi: 10.1016/j.ijrobp.2008.09.006. Int J Radiat Oncol Biol Phys. 2009. PMID: 19100923 Free PMC article.
-
SEA-Net: Structure-Enhanced Attention Network for Limited-Angle CBCT Reconstruction of Clinical Projection Data.IEEE Trans Instrum Meas. 2023;72:4507613. doi: 10.1109/tim.2023.3318712. Epub 2023 Oct 9. IEEE Trans Instrum Meas. 2023. PMID: 38957474 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical