Quality assurance of image-guidance technologies
- PMID: 17903705
- DOI: 10.1016/j.semradonc.2007.07.002
Quality assurance of image-guidance technologies
Abstract
The introduction of image-guided radiotherapy systems (IGS) allows improved management of geometric variations in patient setup and internal organ motion. Commercially available technologies, based on ultrasound, projection radiography, or cone-beam CT, have been widely adopted in radiation therapy. All rely on the comparison of daily images with reference images of the patient anatomy to ensure coincidence of the treatment and planned isocenters. This article reviews how IGS hardware and software are commissioned for clinical release and what quality control checks are required to ensure consistent and reproducible geometric accuracy. As image guidance significantly modifies conventional radiotherapy processes, recommendations and potential issues are discussed to facilitate the introduction of image guidance into the clinical environment.
Similar articles
-
Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy.Int J Radiat Oncol Biol Phys. 2008;71(1 Suppl):S57-61. doi: 10.1016/j.ijrobp.2007.06.086. Int J Radiat Oncol Biol Phys. 2008. PMID: 18406939
-
Quality assurance needs for modern image-based radiotherapy: recommendations from 2007 interorganizational symposium on "quality assurance of radiation therapy: challenges of advanced technology".Int J Radiat Oncol Biol Phys. 2008;71(1 Suppl):S2-12. doi: 10.1016/j.ijrobp.2007.08.080. Int J Radiat Oncol Biol Phys. 2008. PMID: 18406928
-
Quality assurance of immobilization and target localization systems for frameless stereotactic cranial and extracranial hypofractionated radiotherapy.Int J Radiat Oncol Biol Phys. 2008;71(1 Suppl):S131-5. doi: 10.1016/j.ijrobp.2007.05.097. Int J Radiat Oncol Biol Phys. 2008. PMID: 18406912
-
In-room CT techniques for image-guided radiation therapy.Med Dosim. 2006 Spring;31(1):30-9. doi: 10.1016/j.meddos.2005.12.010. Med Dosim. 2006. PMID: 16551527 Review.
-
Current brachytherapy quality assurance guidance: does it meet the challenges of emerging image-guided technologies?Int J Radiat Oncol Biol Phys. 2008;71(1 Suppl):S18-22. doi: 10.1016/j.ijrobp.2007.07.2388. Int J Radiat Oncol Biol Phys. 2008. PMID: 18406923
Cited by
-
Accuracy of automatic couch corrections with on-line volumetric imaging.J Appl Clin Med Phys. 2009 Oct 7;10(4):106-116. doi: 10.1120/jacmp.v10i4.3056. J Appl Clin Med Phys. 2009. PMID: 19918232 Free PMC article.
-
Evaluation of IsoCal geometric calibration system for Varian linacs equipped with on-board imager and electronic portal imaging device imaging systems.J Appl Clin Med Phys. 2014 May 8;15(3):4688. doi: 10.1120/jacmp.v15i3.4688. J Appl Clin Med Phys. 2014. PMID: 24892342 Free PMC article.
-
Evaluation of the truebeam machine performance check (MPC) geometric checks for daily IGRT geometric accuracy quality assurance.J Appl Clin Med Phys. 2017 May;18(3):200-206. doi: 10.1002/acm2.12064. Epub 2017 Mar 22. J Appl Clin Med Phys. 2017. PMID: 28332342 Free PMC article.
-
An AI-based universal phantom analysis method based on XML-SVG wireframes with novel functional object identifiers.Phys Med Biol. 2023 Jul 14;68(14):10.1088/1361-6560/acdb44. doi: 10.1088/1361-6560/acdb44. Phys Med Biol. 2023. PMID: 37267994 Free PMC article.
-
Automated quality assurance for image-guided radiation therapy.J Appl Clin Med Phys. 2009 Jan 27;10(1):71-79. doi: 10.1120/jacmp.v10i1.2919. J Appl Clin Med Phys. 2009. PMID: 19223842 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials