Manual rotation in occiput posterior or transverse positions: risk factors and consequences on the cesarean delivery rate
- PMID: 17906022
- DOI: 10.1097/01.AOG.0000281666.04924.be
Manual rotation in occiput posterior or transverse positions: risk factors and consequences on the cesarean delivery rate
Abstract
Objective: To identify the risk factors for failure of manual rotation in patients with occiput posterior or transverse positions during labor and to study the cesarean rate according to the success of the rotation.
Methods: Case-control study comparing failure and success of manual rotation. Cases were all fetuses for whom rotation failed. We used computerized randomization (without matching) to select one control with a successful rotation during the same period for each case with a failed rotation. Maternal, neonatal, and obstetric risk factors for failed rotation were studied with bivariable and multivariable analyses. Mode of delivery was analyzed according to success of the rotation.
Results: During the study period, manual rotations were performed in 796 patients. The procedure failed in 77 (9.7%) women. Attempted rotation before full dilatation tripled the risk of failure in comparison with rotation at full dilatation (adjusted odds ratio 3.4, 95% confidence interval 1.3-8.6), and rotation for failure to progress quadrupled that risk in comparison with prophylactic rotation (adjusted odds ratio 3.3, 95% confidence interval 1.2-8.5). Failure of manual rotation was associated with a higher cesarean delivery rate than was success (58.8% compared with 3.8%, P<.001). All women with unsuccessful manual rotations who delivered vaginally delivered in the occiput posterior position, and all women with successful manual rotation delivering vaginally delivered in the occiput anterior position.
Conclusion: Manual rotation may be an effective technique for reducing the cesarean delivery rate in patients with an occiput posterior or transverse position during labor. The success or failure of attempted manual rotation depends upon obstetric conditions, including the indication for rotation and cervical dilatation.
Similar articles
-
Manual rotation of the fetal occiput: predictors of success and delivery.Am J Obstet Gynecol. 2006 May;194(5):e7-9. doi: 10.1016/j.ajog.2006.01.029. Am J Obstet Gynecol. 2006. PMID: 16647899
-
Effect of fetal position on second-stage duration and labor outcome.Obstet Gynecol. 2005 Apr;105(4):763-72. doi: 10.1097/01.AOG.0000154889.47063.84. Obstet Gynecol. 2005. PMID: 15802403
-
Prophylactic manual rotation of occiput posterior and transverse positions to decrease operative delivery: the PROPOP randomized clinical trial.Am J Obstet Gynecol. 2021 Oct;225(4):444.e1-444.e8. doi: 10.1016/j.ajog.2021.05.020. Epub 2021 May 24. Am J Obstet Gynecol. 2021. PMID: 34033811 Clinical Trial.
-
Labor with abnormal presentation and position.Obstet Gynecol Clin North Am. 2005 Jun;32(2):165-79. doi: 10.1016/j.ogc.2004.12.005. Obstet Gynecol Clin North Am. 2005. PMID: 15899353 Review.
-
The fetal occiput posterior position: state of the science and a new perspective.Birth. 2010 Mar;37(1):61-71. doi: 10.1111/j.1523-536X.2009.00380.x. Birth. 2010. PMID: 20402724 Review.
Cited by
-
Persistent Occiput Posterior position - OUTcomes following manual rotation (POP-OUT): study protocol for a randomised controlled trial.Trials. 2015 Mar 15;16:96. doi: 10.1186/s13063-015-0603-7. Trials. 2015. PMID: 25872776 Free PMC article. Clinical Trial.
-
Babies in occiput posterior position are significantly more likely to require an emergency cesarean birth compared with babies in occiput transverse position in the second stage of labor: A prospective observational study.Acta Obstet Gynecol Scand. 2020 Apr;99(4):537-545. doi: 10.1111/aogs.13765. Epub 2019 Dec 12. Acta Obstet Gynecol Scand. 2020. PMID: 31667835 Free PMC article.
-
The impact of manual rotation of the occiput posterior position on spontaneous vaginal delivery rate: study protocol for a randomized clinical trial (RMOS).Trials. 2018 Feb 14;19(1):109. doi: 10.1186/s13063-018-2497-7. Trials. 2018. PMID: 29444695 Free PMC article.
-
Transverse occiput position: Using manual Rotation to aid Normal birth and improve delivery OUTcomes (TURN-OUT): A study protocol for a randomised controlled trial.Trials. 2015 Aug 18;16:362. doi: 10.1186/s13063-015-0854-3. Trials. 2015. PMID: 26282668 Free PMC article. Clinical Trial.
-
Prophylactic manual rotation for fetal malposition to reduce operative delivery.Cochrane Database Syst Rev. 2014 Dec 22;2014(12):CD009298. doi: 10.1002/14651858.CD009298.pub2. Cochrane Database Syst Rev. 2014. Update in: Cochrane Database Syst Rev. 2025 Jul 18;7:CD009298. doi: 10.1002/14651858.CD009298.pub3. PMID: 25532081 Free PMC article. Updated.