The Joint Committee for Traceability in Laboratory Medicine (JCTLM): a global approach to promote the standardisation of clinical laboratory test results
- PMID: 17909615
- PMCID: PMC1994110
The Joint Committee for Traceability in Laboratory Medicine (JCTLM): a global approach to promote the standardisation of clinical laboratory test results
Abstract
Clinical laboratories are moving towards global standardisation to produce equivalent test results across space and time. Standardisation allows use of evidence-based medicine, eliminates the need of method-specific reference intervals, decision levels and cut-offs, and can be achieved by application of metrological principles. For example, in vitro diagnostics (IVD) manufacturers can make kit calibrators traceable to internationally recognised reference materials and reference methods. The first step towards standardisation is to identify appropriate reference materials and methods. This has been undertaken by a new international consortium, the Joint Committee for Traceability in Laboratory Medicine (JCTLM), formed in 2002. It brings together experts representing the clinical laboratory profession, government agencies, and manufacturers, to promote international comparability, reliability, and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. Through the efforts of the JCTLM, manufacturers are able to assign values to kit calibrators with consistency using appropriate higher order reference materials and methods, and traceability flowcharts, according to ISO Standards to ensure accuracy of test results and to promote assay performance harmonisation. Users of assay kits can assess suitability of calibrators on the basis of acceptable reference materials and/or methods identified by the JCTLM. The JCTLM exemplifies the dynamic nature of clinical laboratory medicine, the inherent spirit of cooperation among professionals in this scientific field, and the international desire to strive for the highest level of clinical laboratory practice for the benefit of patients.
Figures
Similar articles
-
The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.Clin Chim Acta. 2016 Jan 30;453:86-94. doi: 10.1016/j.cca.2015.11.016. Epub 2015 Nov 23. Clin Chim Acta. 2016. PMID: 26616732 Review.
-
Optimizing Available Tools for Achieving Result Standardization: Value Added by Joint Committee on Traceability in Laboratory Medicine (JCTLM).Clin Chem. 2021 Nov 26;67(12):1590-1605. doi: 10.1093/clinchem/hvab178. Clin Chem. 2021. PMID: 34633037
-
Implementation of metrological traceability in laboratory medicine: where we are and what is missing.Clin Chem Lab Med. 2020 Jul 28;58(8):1200-1204. doi: 10.1515/cclm-2019-1128. Clin Chem Lab Med. 2020. PMID: 32069227 Review.
-
Implementing metrological traceability of C-reactive protein measurements: consensus summary from the Joint Committee for Traceability in Laboratory Medicine Workshop.Clin Chem Lab Med. 2023 May 30;61(9):1558-1560. doi: 10.1515/cclm-2023-0498. Print 2023 Aug 28. Clin Chem Lab Med. 2023. PMID: 37253275
-
Traceability as a unique tool to improve standardization in laboratory medicine.Clin Biochem. 2009 Mar;42(4-5):236-40. doi: 10.1016/j.clinbiochem.2008.09.098. Clin Biochem. 2009. PMID: 19863912
Cited by
-
Standardization, Harmonization, and Realization.Point Care. 2008 Sep 1;7(3):110-112. doi: 10.1097/POC.0b013e318182fa85. Point Care. 2008. PMID: 19960109 Free PMC article.
-
The Oral Glucose Tolerance Test-Is It Time for a Change?-A Literature Review with an Emphasis on Pregnancy.J Clin Med. 2020 Oct 27;9(11):3451. doi: 10.3390/jcm9113451. J Clin Med. 2020. PMID: 33121014 Free PMC article. Review.
-
Wearable sensors enable personalized predictions of clinical laboratory measurements.Nat Med. 2021 Jun;27(6):1105-1112. doi: 10.1038/s41591-021-01339-0. Epub 2021 May 24. Nat Med. 2021. PMID: 34031607 Free PMC article.
-
Compliance to specifications in an external quality assurance program: did new biological variation estimates of the European Federation of Laboratory Medicine (EFLM) affect the quality of laboratory results?Adv Lab Med. 2023 Nov 23;4(4):379-386. doi: 10.1515/almed-2023-0155. eCollection 2023 Dec. Adv Lab Med. 2023. PMID: 38106488 Free PMC article.
-
Standardization in laboratory medicine: Two years' experience from category 1 EQA programs in Spain.Biochem Med (Zagreb). 2019 Feb 15;29(1):010701. doi: 10.11613/BM.2019.010701. Epub 2018 Dec 15. Biochem Med (Zagreb). 2019. PMID: 30591811 Free PMC article.
References
-
- Panteghini M, Gerhardt W, Apple FS, Dati F, Ravkilde J, Wu AH. Quality speci cations for cardiac troponin assays. Clin Chem Lab Med. 2001;39:175–9. - PubMed
-
- Apple FS. Standardization of cardiac markers. Scan J Clin Lab Invest Suppl. 2005;240:107–11. - PubMed
-
- Apple FS, Panteghini M, Ravkilde J, Mair J, Wu AH, Tate J, et al. Quality speci cations for B-type natriuretic peptide assays. Clin Chem. 2005;51:486–93. - PubMed
-
- Christenson RH, Duh SH, Apple FS, Bodor GS, Bunk DM, Panteghini M, et al. Toward standardization of cardiac troponin I measurements part II: assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays. Clin Chem. 2006;52:1685–92. - PubMed
-
- Link RE, Shariat SF, Nguyen CV, Farr A, Weinberg AD, Morton RA, et al. Variation in prostate speci c antigen results from 2 different assay platforms: clinical impact on 2304 patients undergoing prostate cancer screening. J Urol. 2004;171:2234–8. - PubMed
LinkOut - more resources
Full Text Sources