Allison C Aiken et al. Anal Chem. .

Abstract

We present a new elemental analysis (EA) technique for organic species (CHNO) that allows fast on-line analysis (10 s) and reduces the required sample size to approximately 1 ng, approximately 6 orders of magnitude less than standard techniques. The composition of the analyzed samples is approximated by the average elemental composition of the ions from high-resolution electron ionization (EI) mass spectra. EA of organic species can be performed on organic/inorganic mixtures. Elemental ratios for the total organic mass, such as oxygen/carbon (O/C), hydrogen/carbon (H/C), and nitrogen/carbon (N/C), in addition to the organic mass to organic carbon ratio (OM/OC), can be determined. As deviations between the molecular and the ionic composition can appear due to chemical influences on the ion fragmentation processes, the method was evaluated and calibrated using spectra from 20 compounds from the NIST database and from 35 laboratory standards sampled with the high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS). The analysis of AMS (NIST) spectra indicates that quantification of O/C is possible with an error (average absolute value of the relative error) of 30% (17%) for individual species. Precision is much better than accuracy at +/-5% in the absence of air for AMS data. AMS OM/OC has an average error of 5%. Additional calibration is recommended for types of species very different from those analyzed here. EA was applied to organic mixtures and ambient aerosols (sampled at 20 s from aircraft). The technique is also applicable to other EI-HRMS measurements such as direct injection MS.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources