Simplifications in analyzing positron emission tomography data: effects on outcome measures
- PMID: 17921027
- DOI: 10.1016/j.nucmedbio.2007.06.003
Simplifications in analyzing positron emission tomography data: effects on outcome measures
Abstract
Initial validation studies of new radiotracers generally involve kinetic models that require a measured arterial input function. This allows for the separation of tissue binding from delivery and blood flow effects. However, when using a tracer in a clinical setting, it is necessary to eliminate arterial blood sampling due to its invasiveness and the extra burden of counting and analyzing the blood samples for metabolites. In some cases, it may also be necessary to replace dynamic scanning with a shortened scanning period some time after tracer injection, as is done with FDG (F-18 fluorodeoxyglucose). These approximations represent loss of information. In this work, we considered several questions related to this: (1) Do differences in experimental conditions (drug treatments) or populations affect the input function, and what effect, if any, does this have on the final outcome measure? (2) How do errors in metabolite measurements enter into results? (3) What errors are incurred if the uptake ratio is used in place of the distribution volume ratio? (4) Is one- or two-point blood sampling any better for FDG data than the standardized uptake value? and (5) If blood sampling is necessary, what alternatives are there to arterial blood sampling? The first three questions were considered in terms of data from human dynamic positron emission tomography (PET) studies under conditions of baseline and drug pretreatment. Data from [11C]raclopride studies and those from the norepinephrine transporter tracer (S,S)-[11C]O-methyl reboxetine were used. Calculation of a metabolic rate for FDG using the operational equation requires a measured input function. We tested a procedure based on two blood samples to estimate the plasma integral and convolution that occur in the operational equation. There are some tracers for which blood sampling is necessary. Strategies for brain studies involve using the internal carotids in estimating the radioactivity after correcting for partial volume and spillover in order to eliminate arterial sampling. Some venous blood samples are still required for metabolite measurements. The ultimate solution to the problem of arterial sampling may be a wrist scanner, which acts as a small PET camera for imaging the arteries in the wrist. This is currently under development.
Similar articles
-
Measurement of input functions in rodents: challenges and solutions.Nucl Med Biol. 2005 Oct;32(7):679-85. doi: 10.1016/j.nucmedbio.2005.06.012. Nucl Med Biol. 2005. PMID: 16243642
-
Optimization of the injected activity in dynamic 3D PET: a generalized approach using patient-specific NECs as demonstrated by a series of 15O-H2O scans.J Nucl Med. 2009 Sep;50(9):1409-17. doi: 10.2967/jnumed.109.062679. Epub 2009 Aug 18. J Nucl Med. 2009. PMID: 19690021
-
SUV correction for injection errors in FDG-PET examination.Ann Nucl Med. 2007 Dec;21(10):607-13. doi: 10.1007/s12149-007-0068-1. Epub 2007 Dec 25. Ann Nucl Med. 2007. PMID: 18092139
-
Quantification in PET.Radiol Clin North Am. 2004 Nov;42(6):1055-62, viii. doi: 10.1016/j.rcl.2004.08.010. Radiol Clin North Am. 2004. PMID: 15488557 Review.
-
PET kinetic analysis: error consideration of quantitative analysis in dynamic studies.Ann Nucl Med. 2008 Jan;22(1):1-11. doi: 10.1007/s12149-007-0083-2. Ann Nucl Med. 2008. PMID: 18250982 Review.
Cited by
-
Measuring endogenous 5-HT release by emission tomography: promises and pitfalls.J Cereb Blood Flow Metab. 2010 Oct;30(10):1682-706. doi: 10.1038/jcbfm.2010.104. Epub 2010 Jul 28. J Cereb Blood Flow Metab. 2010. PMID: 20664611 Free PMC article. Review.
-
Relative equilibrium plot improves graphical analysis and allows bias correction of standardized uptake value ratio in quantitative 11C-PiB PET studies.J Nucl Med. 2012 Apr;53(4):622-8. doi: 10.2967/jnumed.111.095927. Epub 2012 Mar 13. J Nucl Med. 2012. PMID: 22414634 Free PMC article.
-
Single time point quantitation of cerebral glucose metabolism by FDG-PET without arterial sampling.EJNMMI Res. 2023 Nov 30;13(1):104. doi: 10.1186/s13550-023-01049-3. EJNMMI Res. 2023. PMID: 38032409 Free PMC article.
-
Effects of low-field magnetic stimulation on brain glucose metabolism.Neuroimage. 2010 Jun;51(2):623-8. doi: 10.1016/j.neuroimage.2010.02.015. Epub 2010 Feb 13. Neuroimage. 2010. PMID: 20156571 Free PMC article.
-
Modular strategies for PET imaging agents.Curr Opin Chem Biol. 2010 Feb;14(1):105-11. doi: 10.1016/j.cbpa.2009.10.005. Epub 2009 Oct 31. Curr Opin Chem Biol. 2010. PMID: 19880343 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources