Aerosolization of mycobacteria and legionellae during dental treatment: low exposure despite dental unit contamination
- PMID: 17922766
- DOI: 10.1111/j.1462-2920.2007.01395.x
Aerosolization of mycobacteria and legionellae during dental treatment: low exposure despite dental unit contamination
Abstract
Dental unit waterlines (DUWL) support growth of a dense microbial population that includes pathogens and hypersensitivity-inducing bacteria, such as Legionella spp. and non-tuberculous mycobacteria (NTM). Dynamic dental instruments connected to DUWL generate aerosols in the work environment, which could allow waterborne pathogens to be aerosolized. The use of the real-time quantitative polymerase chain reaction (qPCR) provides a more accurate estimation of exposure levels compared with the traditional culture approach. Bioaerosol sampling was performed 13 times in an isolated dental treatment room according to a standardized protocol that included four dental prophylaxis treatments. Inhalable dust samples were taken at the breathing zone of both the hygienist and patient and outside the treatment room (control). Total bacteria as well as Legionella spp. and NTM were quantified by qPCR in bioaerosol and DUWL water samples. Dental staff and patients are exposed to bacteria generated during dental treatments (up to 4.3 E + 05 bacteria per m(3) of air). Because DUWL water studied was weakly contaminated by Legionella spp. and NTM, their aerosolization during dental treatment was not significant. As a result, infectious and sensitization risks associated with legionellae and NTM should be minimal.
Similar articles
-
Do contaminated dental unit waterlines pose a risk of infection?J Dent. 2007 Sep;35(9):712-20. doi: 10.1016/j.jdent.2007.06.002. Epub 2007 Aug 6. J Dent. 2007. PMID: 17689168 Review.
-
Risk of exposure to Legionella in dental practice.Ann Agric Environ Med. 2004;11(1):9-12. Ann Agric Environ Med. 2004. PMID: 15236492 Review.
-
Measurement of airborne bacteria and endotoxin generated during dental cleaning.J Occup Environ Hyg. 2009 Feb;6(2):121-30. doi: 10.1080/15459620802633957. J Occup Environ Hyg. 2009. PMID: 19093289
-
Detection of Legionella spp. by fluorescent in situ hybridization in dental unit waterlines.J Appl Microbiol. 2006 May;100(5):955-63. doi: 10.1111/j.1365-2672.2006.02845.x. J Appl Microbiol. 2006. PMID: 16629996
-
Management of dental unit waterline biofilms in the 21st century.Future Microbiol. 2011 Oct;6(10):1209-26. doi: 10.2217/fmb.11.104. Future Microbiol. 2011. PMID: 22004039 Review.
Cited by
-
The Research Gap in Non-tuberculous Mycobacterium (NTM) and Reusable Medical Devices.Front Public Health. 2020 Aug 20;8:399. doi: 10.3389/fpubh.2020.00399. eCollection 2020. Front Public Health. 2020. PMID: 32974254 Free PMC article. No abstract available.
-
Prevalence of Non-Tuberculous Mycobacteria in Hospital Waters of Major Cities of Khuzestan Province, Iran.Front Cell Infect Microbiol. 2016 Apr 13;6:42. doi: 10.3389/fcimb.2016.00042. eCollection 2016. Front Cell Infect Microbiol. 2016. PMID: 27148491 Free PMC article.
-
Do exposures to aerosols pose a risk to dental professionals?Occup Med (Lond). 2018 Sep 13;68(7):454-458. doi: 10.1093/occmed/kqy095. Occup Med (Lond). 2018. PMID: 29931138 Free PMC article.
-
Development of a real-time qPCR method for detection and enumeration of Mycobacterium spp. in surface water.Appl Environ Microbiol. 2010 Nov;76(21):7348-51. doi: 10.1128/AEM.00942-10. Epub 2010 Sep 17. Appl Environ Microbiol. 2010. PMID: 20851986 Free PMC article.
-
Characterization of Biofilm Formation by Mycobacterium chimaera on Medical Device Materials.Front Microbiol. 2021 Jan 11;11:586657. doi: 10.3389/fmicb.2020.586657. eCollection 2020. Front Microbiol. 2021. PMID: 33505365 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous