Diffusion-weighted MR imaging of the normal fetal lung
- PMID: 17924118
- DOI: 10.1007/s00330-007-0784-x
Diffusion-weighted MR imaging of the normal fetal lung
Abstract
To quantify apparent diffusion coefficient (ADC) changes in fetuses with normal lungs and to determine whether ADC can be used in the assessment of fetal lung development. In 53 pregnancies (20-37th weeks of gestation), we measured ADC on diffusion-weighted imaging (DWI) in the apical, middle, and basal thirds of the right lung. ADCs were correlated with gestational age. Differences between the ADCs were assessed. Fetal lung volumes were measured on T2-weighted sequences and correlated with ADCs and with age. ADCs were 2.13 +/- 0.44 microm(2)/ms (mean +/- SD) in the apex, 1.99 +/- 0.42 microm(2)/ms (mean +/- SD) in the middle third, and 1.91 +/- 0.41 microm(2)/ms (mean +/- SD) in the lung base. Neither the individual ADC values nor average ADC values showed a significant correlation with gestational age or with lung volumes. Average ADCs decreased significantly from the lung apex toward the base. Individual ADCs showed little absolute change and heterogeneity. Lung volumes increased significantly during gestation. We have not been able to identify a pattern of changes in the ADC values that correlate with lung maturation. Furthermore, the individual, gravity-related ADC changes are subject to substantial variability and show nonuniform behavior. ADC can therefore not be used as an indicator of lung maturity.
Similar articles
-
Diffusion-weighted MR imaging and apparent diffusion coefficient of the normal fetal lung: preliminary experience.Prenat Diagn. 2008 Aug;28(8):745-8. doi: 10.1002/pd.2041. Prenat Diagn. 2008. PMID: 18567059
-
Diffusion-weighted MRI in lungs of normal fetuses and those with congenital diaphragmatic hernia.Ultrasound Obstet Gynecol. 2009 Dec;34(6):678-86. doi: 10.1002/uog.7326. Ultrasound Obstet Gynecol. 2009. PMID: 19866446
-
A diffusion-weighted template for gestational age-related apparent diffusion coefficient values in the developing fetal brain.Ultrasound Obstet Gynecol. 2007 Sep;30(3):318-24. doi: 10.1002/uog.4078. Ultrasound Obstet Gynecol. 2007. PMID: 17688307
-
Diffusion-weighted MR imaging of fetal lung maturation in sheep: effect of prenatal cortisone administration on ADC values.Eur Radiol. 2013 Jul;23(7):1766-72. doi: 10.1007/s00330-013-2780-7. Epub 2013 Feb 16. Eur Radiol. 2013. PMID: 23417229
-
Diffusion-weighted MR of the brain: methodology and clinical application.Radiol Med. 2005 Mar;109(3):155-97. Radiol Med. 2005. PMID: 15775887 Review. English, Italian.
Cited by
-
Fetal MRI: A Technical Update with Educational Aspirations.Concepts Magn Reson Part A Bridg Educ Res. 2014 Nov;43(6):237-266. doi: 10.1002/cmr.a.21321. Concepts Magn Reson Part A Bridg Educ Res. 2014. PMID: 26225129 Free PMC article.
-
Assessment of lung development in isolated congenital diaphragmatic hernia using signal intensity ratios on fetal MR imaging.Eur Radiol. 2010 Apr;20(4):829-37. doi: 10.1007/s00330-009-1633-x. Epub 2009 Nov 5. Eur Radiol. 2010. PMID: 19890648
-
The application of in utero magnetic resonance imaging in the study of the metabolic and cardiovascular consequences of the developmental origins of health and disease.J Dev Orig Health Dis. 2021 Apr;12(2):193-202. doi: 10.1017/S2040174420001154. Epub 2020 Dec 14. J Dev Orig Health Dis. 2021. PMID: 33308364 Free PMC article. Review.
-
Transient tachypnoea: new concepts on the commonest neonatal respiratory disorder.Eur Respir Rev. 2025 Feb 5;34(175):240112. doi: 10.1183/16000617.0112-2024. Print 2025 Jan. Eur Respir Rev. 2025. PMID: 39909500 Free PMC article. Review.
-
Fetal lung apparent diffusion coefficient measurement using diffusion-weighted MRI at 3 Tesla: Correlation with gestational age.J Magn Reson Imaging. 2016 Dec;44(6):1650-1655. doi: 10.1002/jmri.25294. Epub 2016 May 9. J Magn Reson Imaging. 2016. PMID: 27159847 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous