Comparative Study
. 2008 Jan;18(1):51-8.
doi: 10.1007/s00330-007-0738-3. Epub 2007 Oct 9.

Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma

Affiliations
Comparative Study

Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma

Patric Kröpil et al. Eur Radiol. 2008 Jan.

Abstract

This study compares the sensitivity of whole-body multidetector CT (MDCT) and conventional radiography (CR) in the staging of multiple myeloma (MM). Twenty-nine patients with MM underwent a staging examination both by MDCT and CR. CT examination was performed with a collimation of 64x0.6 mm, a tube potential of 100 kVp, an effective tube current-time product of 100 mAs and automatic dose modulation as low-dose protocol. Number, size and diagnostic confidence of osteolytic lesions were determined and compared. The effective dose of MDCT and CR was assessed. Using MDCT, the detection of osteolysis was increased seven-fold concerning the spine. Ninety-seven lesions in 18 patients were detected exclusively by MDCT. The detection rate concerning the spine, pelvic skeleton and thoracic cage was significantly higher (p< or =0.001), and diagnostic confidence was increased by MDCT (p<0.02) compared to CR. Therapy was changed after MDCT in 18.2% of the patients with a clinical suspicion of progressive disease. The estimated effective dose of MDCT (4.8 mSv) and CR (1.7 mSv) was comparable. In conclusion, MDCT has a significantly higher sensitivity and reliability in the detection of osteolysis than CR and can be recommended as standard imaging method in the staging of MM.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Radiat Prot Dosimetry. 2005;114(1-3):308-12 - PubMed
    1. Eur Radiol. 2003 May;13(5):976-80 - PubMed
    1. Radiol Med. 1997 Jun;93(6):669-75 - PubMed
    1. Br J Haematol. 1995 Nov;91(3):658-60 - PubMed
    1. Eur J Nucl Med Mol Imaging. 2006 May;33(5):525-31 - PubMed

Publication types