Analytical performance of an ultrasonic particle focusing flow cytometer
Abstract
Creation of inexpensive small-flow cytometers is important for applications ranging from disease diagnosis in resource-poor areas to use in distributed sensor networks. In conventional-flow cytometers, hydrodynamics focus particles to the center of a flow stream for analysis, which requires sheath fluid that increases consumable use and waste while dramatically reducing instrument portability. Here we have evaluated, using quantitative measurements of fluorescent microspheres and cells, the performance of a flow cytometer that uses acoustic energy to focus particles to the center of a flow stream. This evaluation demonstrated measurement precision for fluorescence and side scatter CVs for alignment microspheres of 2.54% and 7.7%, respectively. Particles bearing 7 x 10(3) fluorophores were well resolved in a background of 50 nM free fluorophore. The lower limit of detection was determined to be about 650 fluorescein molecules. Analysis of Chinese hamster cells on the system demonstrated that acoustic focusing had no effect on cellular viability. These results indicate that the ultrasonic flow cytometer has the necessary performance for most flow cytometry applications. Furthermore, through robust engineering approaches and the combination of acoustic focusing with low-cost light sources, detectors, and data acquisition systems, it will be possible to achieve a low-cost, truly portable flow cytometer.
Similar articles
-
Ultrasonic particle-concentration for sheathless focusing of particles for analysis in a flow cytometer.Cytometry A. 2006 Feb;69(2):66-74. doi: 10.1002/cyto.a.20205. Cytometry A. 2006. PMID: 16419065
-
Evaluation of a green laser pointer for flow cytometry.Cytometry A. 2007 Oct;71(10):809-17. doi: 10.1002/cyto.a.20454. Cytometry A. 2007. PMID: 17712796
-
Reduced gravity evaluation of potential spaceflight-compatible flow cytometer technology.Cytometry B Clin Cytom. 2005 Jul;66(1):1-9. doi: 10.1002/cyto.b.20057. Cytometry B Clin Cytom. 2005. PMID: 15924305
-
Flow cytometry instrumentation in research and clinical laboratories.Clin Lab Sci. 1993 May-Jun;6(3):167-73. Clin Lab Sci. 1993. PMID: 10146217 Review.
-
Microfluidic impedance-based flow cytometry.Cytometry A. 2010 Jul;77(7):648-66. doi: 10.1002/cyto.a.20910. Cytometry A. 2010. PMID: 20583276 Review.
Cited by
-
Staged Inertial Microfluidic Focusing for Complex Fluid Enrichment.RSC Adv. 2015;5:53857-53864. doi: 10.1039/c5ra10634f. RSC Adv. 2015. PMID: 26185618 Free PMC article.
-
Acoustofluidic waveguides for localized control of acoustic wavefront in microfluidics.Microfluid Nanofluidics. 2017 Aug;21:132. doi: 10.1007/s10404-017-1971-y. Epub 2017 Jul 21. Microfluid Nanofluidics. 2017. PMID: 29358901 Free PMC article.
-
Multiplexed detection of bacteria and toxins using a microflow cytometer.Anal Chem. 2009 Jul 1;81(13):5426-32. doi: 10.1021/ac9005827. Anal Chem. 2009. PMID: 19496600 Free PMC article.
-
Nano/Microfluidics for diagnosis of infectious diseases in developing countries.Adv Drug Deliv Rev. 2010 Mar 18;62(4-5):449-57. doi: 10.1016/j.addr.2009.11.016. Epub 2009 Nov 30. Adv Drug Deliv Rev. 2010. PMID: 19954755 Free PMC article. Review.
-
Flow Cytometry: Impact on Early Drug Discovery.J Biomol Screen. 2015 Jul;20(6):689-707. doi: 10.1177/1087057115578273. Epub 2015 Mar 24. J Biomol Screen. 2015. PMID: 25805180 Free PMC article. Review.