[Combined anti-bradycardia/anti-tachycardia pacemaker-cardioverter-defibrillator systems in patients with recurrent ventricular tachyarrhythmias]
- PMID: 1792808
[Combined anti-bradycardia/anti-tachycardia pacemaker-cardioverter-defibrillator systems in patients with recurrent ventricular tachyarrhythmias]
Abstract
In 41 patients with recurrent sustained ventricular tachycardia and/or ventricular fibrillation an integrated pacemaker-defibrillator-system (PCD, Medtronic, model 7216 A or 7217 B) was implanted. In 21 out of 24 (88%) patients a new transvenous implantation technique in combination with a subcutaneous patch electrode was used. The implanted devices comprise antibradycardiac pacemaker functions, two different forms of antitachycardiac pacemaker functions (ramp and burst pacing), and internal cardioversion or defibrillation capabilities. During a mean follow-up of 8 months 147 episodes of ventricular tachycardia were detected, 131 of them were terminated successfully by antitachycardiac pacing; in 13 episodes internal cardioversion was applied to revert ventricular tachycardia. Twenty-seven episodes of ventricular fibrillation or rapid ventricular tachycardia (greater than 200/min) were detected and successfully terminated by internal defibrillation. In six patients with intermittent rapid atrial fibrillation, change of antiarrhythmic therapy was required to avoid activation of the device. The new integrated pacemaker-defibrillator systems improve therapy in patients with life-threatening tachyarrhythmias by reducing the number of internal cardioversions/defibrillations; the non-thoracotomy approach reduces the post operative risk.
Similar articles
-
[Initial clinical experiences with a transvenous-subcutaneous defibrillation system].Z Kardiol. 1991 Nov;80(11):657-64. Z Kardiol. 1991. PMID: 1792807 German.
-
Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system.Arch Intern Med. 1989 Oct;149(10):2333-9. Arch Intern Med. 1989. PMID: 2802898
-
Initial clinical experience with the pacemaker-cardioverter-defibrillator.Can J Cardiol. 1990 May;6(4):147-56. Can J Cardiol. 1990. PMID: 2344560
-
[The implantable automatic cardioverter-defibrillator].Herz. 1990 Apr;15(2):111-25. Herz. 1990. PMID: 2188891 Review. German.
-
Use of electrical pacemakers in the treatment of ventricular tachycardia and ventricular fibrillation.Cardiovasc Clin. 1985;16(1):215-37. Cardiovasc Clin. 1985. PMID: 3915712 Review.
Cited by
-
Clinical experience with the transvenous Medtronic Pacer Cardioverter Defibrillator (PCD) System.Tex Heart Inst J. 1993;20(4):264-70. Tex Heart Inst J. 1993. PMID: 8298322 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical