EEG versus MEG localization accuracy: theory and experiment
- PMID: 1793693
- DOI: 10.1007/BF01132766
EEG versus MEG localization accuracy: theory and experiment
Abstract
We first review the theoretical and computer modelling studies concerning localization accuracy of EEG and MEG, both separately and together; the source is here a dipole. The results show that, of the three causes of localization errors, noise and head modelling errors have about the same effect on EEG and MEG localization accuracies, while the results for measurement placement errors are inconclusive. Thus, these results to date show no significant superiority of MEG over EEG localization accuracy. Secondly, we review the experimental findings, where there are again localization accuracy studies of EEG and MEG both separately and together. The most significant EEG-only study was due to dipoles implanted in the heads of patients, and produced an average localization error of 20 mm. Various MEG-only studies gave an average error of 2-3 mm in saline spheres and 4-8 mm in saline-filled skulls. In the one study where EEG and MEG localization were directly compared in the same actual head, again using dipoles implanted in patients, the average EEG and MEG errors of localization were 10 and 8 mm respectively. The MEG error was later confirmed by a similar (but MEG-only) experiment in another study, using a more elaborate MEG system. In summary, both theory and experiment suggests that the MEG offers no significant advantage over the EEG in the task of localizing a dipole source. The main use of the MEG, therefore, should be based on the proven feature that the MEG signal from a radial source is highly suppressed, allowing it to complement the EEG in selecting between competing source configurations.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
MEG versus EEG localization test using implanted sources in the human brain.Ann Neurol. 1990 Dec;28(6):811-7. doi: 10.1002/ana.410280613. Ann Neurol. 1990. PMID: 2285267
-
Error bounds for EEG and MEG dipole source localization.Electroencephalogr Clin Neurophysiol. 1993 May;86(5):303-21. doi: 10.1016/0013-4694(93)90043-u. Electroencephalogr Clin Neurophysiol. 1993. PMID: 7685264
-
Source localization of EEG versus MEG: empirical comparison using visually evoked responses and theoretical considerations.Brain Topogr. 1991 Winter;4(2):133-42. doi: 10.1007/BF01132770. Brain Topogr. 1991. PMID: 1793687
-
Controversies in clinical neurophysiology. MEG is superior to EEG in the localization of interictal epileptiform activity: Con.Clin Neurophysiol. 2004 May;115(5):1010-20. doi: 10.1016/j.clinph.2003.12.010. Clin Neurophysiol. 2004. PMID: 15066524 Review.
-
Localization of partial epilepsy using magnetic and electric measurements.Epilepsia. 1991;32 Suppl 5:S29-40. Epilepsia. 1991. PMID: 1743168 Review.
Cited by
-
The effect of ageing on fMRI: Correction for the confounding effects of vascular reactivity evaluated by joint fMRI and MEG in 335 adults.Hum Brain Mapp. 2015 Jun;36(6):2248-69. doi: 10.1002/hbm.22768. Epub 2015 Feb 27. Hum Brain Mapp. 2015. PMID: 25727740 Free PMC article.
-
Update on epilepsy and cerebral localization.Curr Neurol Neurosci Rep. 2007 Nov;7(6):498-507. doi: 10.1007/s11910-007-0077-4. Curr Neurol Neurosci Rep. 2007. PMID: 17999896 Review.
-
Comparing Features for Classification of MEG Responses to Motor Imagery.PLoS One. 2016 Dec 16;11(12):e0168766. doi: 10.1371/journal.pone.0168766. eCollection 2016. PLoS One. 2016. PMID: 27992574 Free PMC article.
-
Parametrizing the Conditionally Gaussian Prior Model for Source Localization with Reference to the P20/N20 Component of Median Nerve SEP/SEF.Brain Sci. 2020 Dec 3;10(12):934. doi: 10.3390/brainsci10120934. Brain Sci. 2020. PMID: 33287441 Free PMC article.
-
Head surface digitization and registration: a method for mapping positions on the head onto magnetic resonance images.Brain Topogr. 1994 Spring;6(3):185-92. doi: 10.1007/BF01187708. Brain Topogr. 1994. PMID: 8204405