[Active clinical surveillance for detection of Legionnaires' disease: implications for health care structures]
- PMID: 17937322
[Active clinical surveillance for detection of Legionnaires' disease: implications for health care structures]
Erratum in
- Ann Ig. 2007 Nov-Dec;19(6):8 p following 593. Concetti, S [corrected to Cencetti, S]
Abstract
In an university hospital of about 900 beds, a clinical surveillance was activated to detect cases of Legionnaires' disease in patients affected by community and/or nosocomial-acquired pneumonia. In the hospital Legionella spp was detected in the hot water distribution system and various disinfecting and control procedures were adopted to reduce contamination. Contemporary, the clinical surveillance began with the systematic detection of Legionella urinary antigen among recovered pneumonia, seroconversion as confirmation test and the collection of respiratory secretions or other biological materials to isolate the microorganism in patients positive to the urinary antigen. From September 2003 to May 2005, 486 pneumonia were followed, 98 of which considered of nosocomial origin. In total, 15 cases of community-acquired Legionnaires' disease were detected by the urinary test, whereas no cases of nosocomial origin were found. The characteristics of the detected cases are described in comparison with the other pneumonia and the surveillance cost was evaluated. The systematic clinical surveillance for Legionella infections is feasible with limit costs, allows to detect community-acquired cases otherwise unknown and to ascertain the absence/presence of nosocomial-acquired pneumonia, irrespective of the environment contamination.
Similar articles
-
A recurrent outbreak of nosocomial legionnaires' disease detected by urinary antigen testing: evidence for long-term colonization of a hospital plumbing system.Infect Control Hosp Epidemiol. 1998 Dec;19(12):905-10. Infect Control Hosp Epidemiol. 1998. PMID: 9872526
-
Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature above 55 degrees C: experience from a 10-year surveillance programme in a district general hospital.J Hosp Infect. 2002 Mar;50(3):213-9. doi: 10.1053/jhin.2002.1185. J Hosp Infect. 2002. PMID: 11886198
-
Detecting legionellosis by unselected culture of respiratory tract secretions and developing links to hospital water strains.J Hosp Infect. 1999 Apr;41(4):301-11. doi: 10.1053/jhin.1998.0517. J Hosp Infect. 1999. PMID: 10392336
-
[Community-acquired pneumonia due to Legionella pneumophila serogroup 1. Study of 97 cases].Enferm Infecc Microbiol Clin. 2003 Oct;21(8):394-400. Enferm Infecc Microbiol Clin. 2003. PMID: 14525703 Review. Spanish.
-
[How to reduce the risk of Legionnaires' disease?].Rev Prat. 2005 Nov 30;55(18):1983-9. Rev Prat. 2005. PMID: 16419902 Review. French.