Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Feb;101(3):341-4.
doi: 10.1111/j.1464-410X.2007.07280.x. Epub 2007 Oct 17.

Acute pyelonephritis: comparison of diagnosis with computed tomography and contrast-enhanced ultrasonography

Affiliations
Comparative Study

Acute pyelonephritis: comparison of diagnosis with computed tomography and contrast-enhanced ultrasonography

Michael Mitterberger et al. BJU Int. 2008 Feb.

Abstract

Objective: To assess the value of contrast-enhanced ultrasonography (US) with the contrast pulse-sequence (CPS) technique for detecting renal parenchymal changes in acute pyelonephritis (APN), compared with contrast-enhanced computed tomography (CT) as the reference standard.

Patients and methods: We examined 100 patients (82 women, 18 men; mean age 30.2 years, range 18-67); children (those aged <18 years) were excluded from the study. All patients had clinical symptoms suggestive of APN. For the US a Sequoia 512 (Acuson, Mountain View, CA, USA) unit including Cadence CPS technology, with a 6C2 probe, was used. A bolus of a 2.4-mL US contrast agent SonoVue (Bracco, Milan, Italy) was injected. For CT a multislice 16-row unit was used (Sensation 16, Siemens, Erlangen, Germany), at a table speed of 2.5 mm/s and a slice thickness of 3 mm; 100 mL of intravenous iodinated contrast agent (flow 3 mL/s) was injected.

Results: On contrast CT, 84 patients (84%) had renal parenchymal changes suggestive of APN; on contrast US, 82 of the 84 (98%) showed renal parenchymal changes, and APN was correctly diagnosed. Seventy-six patients (90%) had unilateral and eight (10%) had bilateral APN, and in two (2%) with APN the diagnosis could not be confirmed by US/CPS (false-negative). No false-positive findings were detected on US/CPS, which had a sensitivity of 98%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 89%.

Conclusion: CPS/US is accurate for detecting parenchymal changes in APN; it is very sensitive and specific, and allows small renal parenchymal changes to be detected with no radiation exposure.

PubMed Disclaimer

LinkOut - more resources