Comparative Study
. 2007 Dec;45(12):3954-7.
doi: 10.1128/JCM.01501-07. Epub 2007 Oct 17.

Detection of inducible clindamycin resistance in staphylococci by broth microdilution using erythromycin-clindamycin combination wells

Affiliations
Comparative Study

Detection of inducible clindamycin resistance in staphylococci by broth microdilution using erythromycin-clindamycin combination wells

Jana M Swenson et al. J Clin Microbiol. 2007 Dec.

Abstract

A study conducted by 11 laboratories investigated the ability of four combinations of erythromycin (ERY) and clindamycin (CC) (ERY and CC at 4 and 0.5, 6 and 1, 8 and 1.5, and 0.5 and 2 microg/ml) in a single well of a broth microdilution panel to predict the presence of inducible CC resistance. Each laboratory tested approximately 30 Staphylococcus aureus isolates and 20 coagulase-negative staphylococcus (CoNS) isolates in a panel using cation-adjusted Mueller-Hinton broth from three different manufacturers. Only the strains resistant to ERY and those susceptible or intermediate to CC were included in the analysis (S. aureus, n = 333; CoNS, n = 97). Results of the D-zone test were used as the gold standard. After an 18-h incubation, the combination of 4 microg/ml ERY and 0.5 microg/ml CC performed the best, with 98 to 100% sensitivity and 100% specificity for both organism groups. After a 24-h incubation, the ERY-CC combinations of 4 and 0.5, 6 and 1, and 8 and 1.5 microg/ml correlated well with the D-zone test.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Clinical and Laboratory Standards Institute/NCCLS. 2006. Methods for dilution antimicrobial susceptibility tests for bacteria that grow aerobically; approved standard-7th ed. CLSI/NCCLS M7-A7. Clinical and Laboratory Standards Institute, Wayne, PA.
    1. Clinical and Laboratory Standards Institute/NCCLS. 2006. Performance standards for antimicrobial disk susceptibility tests; approved standard-9th ed. CLSI/NCCLS M2-A9. Clinical and Laboratory Standards Institute, Wayne, PA.
    1. Clinical and Laboratory Standards Institute/NCCLS. 2008. Performance standards for antimicrobial susceptibility testing: 18th ed. CLSI/NCCLS M100-S18. Clinical and Laboratory Standards Institute, Wayne, PA.
    1. Clinical and Laboratory Standards Institute/NCCLS. 2007. Performance standards for antimicrobial susceptibility testing: 17th ed. CLSI/NCCLS M100-S17. Clinical and Laboratory Standards Institute, Wayne, PA.
    1. Fiebelkorn, K. R., S. A. Crawford, M. L. McElmeel, and J. H. Jorgensen. 2003. Practical disk diffusion method for detection of inducible clindamycin resistance in Staphylococcus aureus and coagulase-negative staphylococci. J. Clin. Microbiol. 41:4740-4744. - PMC - PubMed

MeSH terms