[Image postprocessing of aortic CTA and MRA]
- PMID: 17943264
- DOI: 10.1007/s00117-007-1583-8
[Image postprocessing of aortic CTA and MRA]
Abstract
Multiplanar reformation (MPR) is the most relevant tool for patient selection and precise procedural planning and also for analyzing postinterventional complications. Curved MPR is used primarily for semiautomated or completely automated calculation of the centerline of the vascular lumen and to estimate the orthogonal vessel diameter and longitudinal extent. Reproducible and accurate measurement of complex pathologies and courses of vessels extends the range of diagnostic radiology. Contemporary scanner consoles allow automated processing of maximum intensity projections (MIP) and standard MPR and their storage in PACS. To improve patient selection, procedural planning, root-cause analysis postoperatively for assessment of treatment effects and to make better communication of findings to nonradiologists possible, volume rendering techniques (VRT) are a beneficial adjunct to source images. With current algorithms semiautomated segmentation is satisfactory for vessels and bones, but not for low-contrast structures (soft tissues), which still need to be segmented manually. In general, isotropic CT source data are preferable to MR images, which are often anisotropic. In many European countries image postprocessing is still not adequately reimbursed although the doctors making referrals often specifically and emphatically demand 3D visualization and measurements in daily practice.
Similar articles
-
[Reconstruction methods in postprocessing of CT- and MR-angiography of the aorta].Radiologe. 2001 Aug;41(8):689-94. doi: 10.1007/s001170170119. Radiologe. 2001. PMID: 11552384 German.
-
Influence of computed tomography angiography reconstruction software on anatomic measurements and endograft component selection for endovascular abdominal aortic aneurysm repair.J Vasc Surg. 2014 May;59(5):1224-31.e1-3. doi: 10.1016/j.jvs.2013.11.003. Epub 2014 Jan 16. J Vasc Surg. 2014. PMID: 24439321
-
Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool.J Vasc Surg. 2003 Mar;37(3):619-27. doi: 10.1067/mva.2003.143. J Vasc Surg. 2003. PMID: 12618702
-
[CT angiography of the aorta].Radiologe. 2007 Nov;47(11):982-92. doi: 10.1007/s00117-007-1580-y. Radiologe. 2007. PMID: 17938873 Review. German.
-
Imaging modalities for aortic endografting.J Endovasc Surg. 1997 May;4(2):111-23. doi: 10.1583/1074-6218(1997)004<0111:IMFAE>2.0.CO;2. J Endovasc Surg. 1997. PMID: 9184999 Review.
Cited by
-
[Endovascular aortic surgery: management of secondary aortobronchial and aorto-enteral fistulas].Chirurg. 2009 Oct;80(10):947-55. doi: 10.1007/s00104-009-1780-2. Chirurg. 2009. PMID: 19711020 German.
-
The Endurant Stent Graft System: 15-month follow-up report in patients with challenging abdominal aortic anatomies.Langenbecks Arch Surg. 2011 Aug;396(6):801-10. doi: 10.1007/s00423-011-0806-7. Epub 2011 May 25. Langenbecks Arch Surg. 2011. PMID: 21611817
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical