. 2007 Nov 5;603(1):44-50.
doi: 10.1016/j.aca.2007.09.031. Epub 2007 Sep 21.

A new approach for simultaneous determination of Co(II), Ni(II), Cu(II) and Pd(II) using 2-thiophenaldehyde-3-thiosemicarbazone as reagent by solid phase microextraction-high performance liquid chromatography

Affiliations

A new approach for simultaneous determination of Co(II), Ni(II), Cu(II) and Pd(II) using 2-thiophenaldehyde-3-thiosemicarbazone as reagent by solid phase microextraction-high performance liquid chromatography

Varinder Kaur et al. Anal Chim Acta. .

Abstract

A new method is proposed herein for the sorption, separation and simultaneous determination of Co(II), Ni(II), Cu(II) and Pd(II) using 2-thiophenaldehyde-3-thiosemicarbazone (TPTS) as a reagent by solid phase microextraction-high performance liquid chromatography-UV detection. The method is based upon the sorption of metal complexes on polydimethylsiloxane (PDMS) fiber from aqueous solution followed by desorption in the desorption chamber of solid phase microextraction-high performance liquid chromatography (SPME-HPLC) interface. Reversed phase high performance liquid chromatography using acetonitrile:water (65:35) as an eluent on a C18 column has been used to achieve the separation. The effects of agitation, addition of salts, extraction time and desorption time are examined to obtain optimized conditions. The detection limits for Co(II), Ni(II), Cu(II) and Pd(II) are 9, 6, 1 and 7 ng L(-1) based on 3sigma of blank response. The precision is calculated to be less than 3.5% (R.S.D.) for all species. A 10 time enhancement in the signal is observed for SPME when compared with direct analysis. The method is successfully applied to several synthetic mixtures without interference from other common metal ions such as Mo(VI), V(V), Ag(I), Sn(IV), Cd(II), Zn(II), Pb(II), Cr(III) and Cr(VI). The proposed method is tested for the determination of Co(II), Ni(II), Cu(II) and Pd(II) in alloys and water samples spiked with these metal ions.